2-
7
2
INST
ALLA
TION AND CONNECTION
2-5 Connecting to the Robot
2-5
Connecting to the Robot
First make sure that the power to the DRCX controller is turned off, and then connect the robot cable
to the robot I/O connector and motor connector on the front panel of the DRCX controller.
Be sure to fasten the robot I/O cable with the screws so that it will not come loose or be pulled off.
* When the robot cable is disconnected from the controller, an alarm (15: FEEDBACK ERROR
2) is issued. Since the controller is shipped with the robot cable disconnected, an alarm is
always issued when the controller is first turned on. But this is not an equipment problem.
2-5-1 Robot I/O connector and signal table
Mating connector type No.
: 10136-6000EL (3M)
Mating connector cover type No.
: 10336-52A0-008
DRCX's connector type No.
: 10236-52A2JL
Signal Table
Terminal No. Signal name
Description
Terminal No.
Description
PS1+
PS1-
PC1+
PC1-
R1+
R1-
DG
DG
+24V
NC
PG
ORG1
PG
BK1+
BK1+
BK1-
BK1-
FG
PS2+
PS2-
PC2+
PC2-
R2+
R2-
DG
DG
+24V
NC
PG
ORG2
PG
BK2+
BK2+
BK2-
BK2-
FG
Resolver SIN input 1 (+)
Resolver SIN input 1 (-)
Resolver COS input 1 (+)
Resolver COS input 1 (-)
Resolver excitation output 1 (+)
Resolver excitation output 1 (-)
Digital ground
Digital ground
Power supply (24V) for origin sensor
No connection
Power supply (0V) for origin sensor
Origin sensor signal input 1
Power supply (0V) for origin sensor
Brake signal 1 (+)
Brake signal 1 (+)
Brake signal 1 (-)
Brake signal 1 (-)
Frame ground
Resolver SIN input 2 (+)
Resolver SIN input 2 (-)
Resolver COS input 2 (+)
Resolver COS input 2 (-)
Resolver excitation output 2 (+)
Resolver excitation output 2 (-)
Digital ground
Digital ground
Power supply (24V) for origin sensor
No connection
Power supply (0V) for origin sensor
Origin sensor signal input 2
Power supply (0V) for origin sensor
Brake signal 2 (+)
Brake signal 2 (+)
Brake signal 2 (-)
Brake signal 2 (-)
Frame ground
Signal name
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
2-5-2 Motor connector and signal table
Mating connector type No.
: (X-axis) 1-178128-4, (Y-axis) 2-178128-4 (AMP)
Mating connector contact type No.
: 1-175218-5
DRCX's connector type No.
: (X-axis) 1-179553-4, (Y-axis) 2-179553-4
Signal table (X and Y axes)
Terminal No. Signal name
Description
Terminal No.
Description
FG
MU
MV
MW
Frame ground
Motor U-phase output
Motor V-phase output
Motor W-phase output
Signal name
1
2
3
4
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание DRCX
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 9: ...vi MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 129: ...7 12 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 207: ...9 16 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 233: ...10 26 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 281: ...12 10 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...
Страница 310: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...