RIVAGE PM10 System Setup Guide
46
General Specifications
At the time of measurement, all faders are set to nominal. Output impedance of the signal generator is 150Ω.
Frequency response
Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz @20 Hz–20 kHz, reference to the nominal output level @1 kHz
Total harmonic distortion
Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
* An 80kHz, 18 dB/octave low pass filter is used to measure total harmonic distortion.
Hum & noise
*2
Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
Dynamic range
Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
* An IHF-A filter is used to measure dynamic range.
Specifications (CS-R10, CS-R10-S)
Inputs
Outputs
RL
Conditions
Min.
Typ.
Max.
Unit
OMNI IN 1-8
OMNI OUT 1-8
600Ω
GAIN: +66 dB
–0.8
0.0
0.5
dB
Inputs
Outputs
RL
Conditions
Min.
Typ.
Max.
Unit
OMNI IN 1-8
OMNI OUT 1-8
600Ω
+4 dBu@20 Hz–20 kHz, GAIN: +66 dB
0.12
%
OMNI IN 1-8
OMNI OUT 1-8
600Ω
+4 dBu@20 Hz–20 kHz, GAIN: –6 dB
0.05
%
Internal OSC
OMNI OUT 1-8
600Ω
Full scale output @1 kHz
0.02
%
Internal OSC
PHONES
8Ω
Full scale output @1 kHz,
phones level control: max.
0.2
%
Inputs
Outputs
RL
Conditions
Min.
Typ.
Max.
Unit
OMNI IN 1-8
OMNI OUT 1-8
600Ω
Rs= 150Ω, GAIN: +66 dB
Master fader at nominal level and one
Ch fader at nominal level.
–128
EIN
*1
*1.
EIN stands for Equivalent Input Noise.
*2.
An IHF-A filter is used to measure hum & noise level.
dBu
–62
dBu
OMNI IN 1-8
OMNI OUT 1-8
600Ω
Rs= 150Ω, GAIN: –6 dB
Master fader at nominal level and one
Ch fader at nominal level.
–90
-85
dBu
All Inputs
OMNI OUT 1-8
600Ω
Rs= 150Ω, GAIN: –6 dB
Master fader at nominal level and all
OMNI IN1-8 in faders at nominal level.
-76
dBu
—
OMNI OUT 1-8
600Ω
Residual output noise, ST master off.
–92
dBu
—
PHONES
8Ω
Residual output noise, phones level
control min.
–88
dBu
Inputs
Outputs
RL
Conditions
Min.
Typ.
Max.
Unit
OMNI IN 1-8
OMNI OUT 1-8
600Ω
AD + DA, GAIN: –6 dB
114
dB
—
OMNI OUT 1-8
600Ω
DA Converter
116
dB