RIVAGE PM10 System Setup Guide
43
Initializing the unit to
factory default settings
If an error occurs in the unit’s internal memory, or if you
forget the password and cannot operate the unit, you can use
the following procedure to initialize the internal memory.
NOTICE
When you initialize the internal memory, all content that had
been saved in memory will be lost.
Use caution when performing the following steps.
1.
Press the SETUP button on the menu bar in
the touch screen.
The SETUP screen will appear.
2.
Press the MAINTENANCE button.
The MAINTENANCE popup window will appear.
This window includes several pages, which you can
switch between using the tabs located at the top of the
window.
3.
Press the INITIALIZATION tab.
4.
You can select multiple items to be initialized
as required by the desired initialization
method.
• SYSTEM LOG
• LIBRARY
• SCENE
• OTHER
5.
Press the INITIALIZE THIS CONSOLE button.
A dialog box will ask you to confirm the operation.
6.
Press the OK button in the confirmation
dialog box.
The Initialization operation starts.
NOTE
The control surface will restart after initialization.
Adjusting the faders
(Calibration function)
Depending on the environment in which you use the
system, discrepancies may occur in the motion of the
motorized faders. You can use the Calibration function to
correct these discrepancies. The RIVAGE PM10 system
features two types of fader calibration.
NOTE
An alarm message will appear if a problem is detected in the
fader settings while the RIVAGE PM10 system is starting up.
1.
Press the SETUP button on the menu bar in
the touch screen.
The SETUP screen will appear.
2.
Press the MAINTENANCE button.
The MAINTENANCE popup window will appear.
This window includes several pages, which you can
switch between using the tabs located at the top of the
window.
3.
Press the FADER CALIB tab.
The FADER CALIBRATION screen will appear,
which will enable you to adjust the faders.
4.
Select the tab for the desired fader calibration
operation.
Other Operations
Motor Drive
Calibration
Automatically optimizes the motorized
fader movement.
Positioning
Calibration
Calibrates the motorized fader
movement so that the fader knob
positions and the level values stored in
the console (parameter) will match.
Содержание CS-R10
Страница 1: ...CONTROL SURFACE CS R10 CS R10 S System Setup Guide EN ...
Страница 54: ......