RIVAGE PM10 System Setup Guide
47
Crosstalk
@1 kHz Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
* A 22 kHz, 30 dB/octave low pass filter is used to measure crosstalk.
Sampling frequency
Power requirements
Power cable length and temperature range
from/to
to/from
Conditions
Min.
Typ.
Max.
Unit
OMNI IN n
OMNI IN (n-1) or (n+1)
OMNI IN 1-8
adjacent inputs, GAIN: –6 dB
–100
dB
OMNI OUT n
OMNI OUT (n-1) or (n+1)
OMNI OUT 1-8, input to output
–100
dB
Conditions
Min.
Typ.
Max.
Unit
External Clock
Frequency Range Fs= 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
–1000
—
+1000
ppm
Jitter of PLL
*1
*1.
Input clock jitter must be 1 ns or less.
WORD CLOCK IN Fs= 44.1 kHz, 48 kHz, 88.2 kHz,
96 kHz
—
—
10
ns
Internal clock
Frequency
Word clock : int 44.1 kHz
Word clock : int 48 kHz
Word clock : int 88.2 kHz
Word clock : int 96 kHz
—
44.1
48
88.2
96
—
kHz
Accuracy
Word clock : int 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz
–50
—
+50
ppm
Jitter
*2
*2.
Measured at the WORD CLOCK OUT connector.
Word clock : int 44.1 kHz
Word clock : int 48 kHz
Word clock : int 88.2 kHz
Word clock : int 96 kHz
—
—
4.5
4.1
2.3
2.1
ns
Conditions
Min.
Typ.
Max.
Unit
Power consumption
100–240 V 50/60 Hz
—
—
380
W
Heating value
100–240 V 50/60 Hz
—
—
330
kcal/h
Conditions
Min.
Typ.
Max.
Unit
Power cord length
—
250
—
cm
Temperature range
Operating temperature range
0
—
40
°C
Storage temperature range
–20
—
60
°C
Содержание CS-R10
Страница 1: ...CONTROL SURFACE CS R10 CS R10 S System Setup Guide EN ...