Yale YL-SR-320 Скачать руководство пользователя страница 9

9

Mounting the Door/Window Contact

Note:The Door/Window Contact and magnet can be 

changed round as long as there is no more than a 10mm 

gap.

1.

  Find a location on the door/window where you would 

like the device to be mounted. The sensor should be 

on the frame while the magnet should be on the door/

window. Once mounted make sure the tamper switch 

spring is fully depressed.

Mounting using adhesive pads

Clean the mounting surface with a suitable degreaser 

agent. Please note that some surfaces may be unsuitable 

for this mounting method. Please use screw mounting in 

these cases.

Mounting using screws & wall plugs

Loosen the bottom screw and open the door/window 

contact. Knock out the holes on the base as shown. Drill 

holes into the mounting surface using the holes in the 

knockouts on the base as a template. Fit wall plugs (if 

required) and secure with the screws provided.

Mounting the External Siren

Ensure the tamper spring is fully compressed when

the siren is mounted. If there is a gap, pack with a

suitable spacing material.

1.

  Using the large screws and wall plugs provided, screw 

the Siren onto the wall through the 4 mounting holes on 

the Siren base.

2.

  Fix the Siren cover with the securing screw.

Mounting the Panic Button

1.

  Break through the knockouts (where the plastic  

is thinner).

2.

  Using the holes as a template, drill holes in the surface 

and insert wall plugs if fixing into plaster or brick. Screw 

the rear case to the wall. Replace the cover and tighten 

the screw.

Mounting the Smoke Detector

1.

  The base has two mounting slots. Using the slots as 

a template, drill holes and insert the wall plugs if fixing 

to plaster. Screw the rear case to the ceiling using the 

screws provided.

2.

  Replace the main unit onto the bracket.

Display extreme caution when using ladders or steps, 

please follow manufacturer’s instructions.

Be careful when using hand and power tools and follow 

the manufacturer’s guidelines when using them. Take care 

that the correct tools are used. Wear goggles or protective 

clothing where required. The Siren is extremely loud, please 

ensure to retreat to a safe distance before testing.

The gap between the magnet and sensor 

should be no more than 10mm when closed 

(maybe shorter depending upon the actual 

environment).Simply test to see whether the 

magnet is in range of the sensor: hold the 

magnet and sensor in place and then pull 

them apart. If the sensor LED lights up it 

implies the two items are within range.

Содержание YL-SR-320

Страница 1: ...d All accessories are tamper protected Any unauthorised tampering with these items when the system is armed will result in the alarm being triggered 1 Location planning 2 2 Un pack all the parts 4 3 Initial set up 5 3 Additional accessories 6 4 Mounting devices 8 5 Using the system 10 6 About your Alarm System 12 7 Using accessories 13 8 Changing the batteries 15 9 Troubleshooting 17 10 Specificat...

Страница 2: ...switch for reliable operation Extend the System Extend the system in the future to increase your security or as your needs change For example add extra PIR Motion Detectors and extra Door Window Contacts You can add upto 20 devices of which a maximum of 6 of these could be PIR Image or PIR Video Cameras Choosing Location To minimise interference avoid locating devices close to metal framework glas...

Страница 3: ...top of a stairwell or on the centre of hallway ceilings where smoke would most likely be detected Do not mount in corners or above cooking appliances and heaters Install additional detectors if there are closed doors preventing smoke from reaching detectors External Siren Choose a position on an external wall where the siren would be most prominent Mount as high as possible out of easy reach Door ...

Страница 4: ...k to the Server Internet Middle LED Yellow System Fault Further details can be found in the App Middle LED not lit System OK Bottom LED solid red System Armed Bottom LED flashing red System part Armed Bottom LED not lit up System Disarmed Key Pad EF KP 1 Pull out the plastic battery saver tab at the back of the Key Pad This will activate the batteries 2 All accessories in the kit box are already p...

Страница 5: ...d as shown 1 Please ensure you observe battery polarity and insert the battery under the two tabs and click into place see image on page 16 This pet friendly accessory will activate the alarm when large motion is detected Ideal for homes with one small pet less than 25kg Please note when used with large pets there is an increased possibility of false alarms In these scenarios use a Door Window Con...

Страница 6: ...etails Panel Serial Number can be found on the Smart Hub sticker If you encounter errors it is due to the Smart Hub not communicating with our server Please see troubleshooting Warning LED see page 18 You will be asked to set up a password when registration is successful Please use your email and this new password to login via the front page Make sure you keep this manual in a safe and convenient ...

Страница 7: ... Press 8 and 9 together Learn Test button Learn Test button Learn Test button LED One by one press the learn button on the accessory according to below The Smart Hub will beep single or multiple dependent on device when a new device is registered and after a couple of seconds you will see it in your Device List on your App Exit Learn Mode 1 Press and hold the Smart Hub 2 0 Learn button for at leas...

Страница 8: ...t Hub should respond with a chime For the SR PC SR PVC SR PS hold the test button for 3 seconds If the sensor signal reached the Smart Hub it will show up on the last screen see above The radio signal strength is shown by a number under the device name This number ranges from 1 to 9 strongest Where possible please ensure devices show 3 or above for optimal performance When you are happy that all y...

Страница 9: ... the 4 mounting holes on the Siren base 2 Fix the Siren cover with the securing screw Mounting the Panic Button 1 Break through the knockouts where the plastic is thinner 2 Using the holes as a template drill holes in the surface and insert wall plugs if fixing into plaster or brick Screw the rear case to the wall Replace the cover and tighten the screw Mounting the Smoke Detector 1 The base has t...

Страница 10: ...oor when you are upstairs in bed To enable Home Arm you need to choose the sensors to be ignored whilst in this mode It would typically be the bedroom PIR etc if you want to arm your system during the night These sensors should be set to Home Omit in order to be ignored during Home Arm Mode If you wish to trigger an alarm count down with a sensor during Home Arm Mode allowing you time to disarm th...

Страница 11: ... delete unwanted images videos Adding alert email SMS You can add delete email and SMS phone numbers for alert during alarm condition Only burglar events will be reported via SMS while you can choose to have ALL events or Burglar only reported via email Hint our report email will use the email address of report yalehomesystem co uk Save this email address as your VIP Apple iOS or Priority Android ...

Страница 12: ...nder Home Mode but will in Away Mode Home Access Give 30 sec delay when activated under Home Mode Instant Alarm upon activation in Away Mode Entry Zone Upon activation gives a 30 sec delay in both Away and Home Mode To change the exit and entry timer please enable via App Controller Panel Setting Enable or disable supervision detection on the Smart Hub PIR Door Window Contact or Siren can be monit...

Страница 13: ...ency alarm can only be stopped by using the Key Pad Key Pad Key Pad Initialisation If you purchase a Key Pad as an extra Key Pad you will need to initialise it prior to use with the Smart Hub 1 Press Panic button A followed by factory default Key Pad code 0000 2 The LED will now flash slowly indicating it is in test programming mode 3 Press Panic button A followed by the 7 key to set the Key Pad i...

Страница 14: ... a push notification SMS and email Pressing the test button when in an alarm condition will silence the alarm for 10 minutes It will automatically resume smoke detection again after this period Testing Smoke Detector testing should be done on a regular monthly basis Pressing the test button will make the LED flash the audible sounder chime and will send a radio test signal to the Smart Hub when th...

Страница 15: ... takes 3 x AA Lithium batteries The PIR LED will flash for 30 seconds while initialising 4 Refit PIR on base and tighten bottom case screw Ensure tamper spring is fully depressed when re fitting the PIR to the back case If this has not been done correctly this will be indicated by a flashing LED on the PIR External Siren Battery Change When the batteries start getting low the Siren will produce a ...

Страница 16: ... on and the battery change is complete Panic Button Battery Change When the battery is low the LED will glow dimly when the button is pressed The battery is changed as follows 1 Loosen the bottom case screw and take button cover off base 2 Insert the new CR2032 coin cell battery with the side uppermost see picture below 3 Replace button cover Press the button and check that the LED lights If the L...

Страница 17: ...h turn off the power for 30 seconds then turn the power on again for the changes to take effect Door Window Contact Door Window Contact LED lights up Batteries are low or the tamper switch has been disturbed Check that the tamper switch spring is making contact with the mounting surface If the tamper switch is OK please change the battery see page 15 Door Window Contact does not respond to opening...

Страница 18: ...age Video Camera is not learnt into the system or within range of the Smart Hub battery life will be greatly affected while it searches for a connection Smart Hub LED 2 Warning LED Top LED Green Linked to the Server Internet Top LED not lit up No link to the Server Internet Middle LED Yellow System has Fault Further detail will be found in the Yale App Middle LED not lit OK Bottom LED solid red Sy...

Страница 19: ...mera Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 2 4GHz Power supply 2 x AA 1 5V alkaline batteries Movement detection range 110 PIR Video Camera Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 2 4GHz Power supply 3 x AA Lithium batteries Motion Detector range 1...

Страница 20: ...lands England WV13 3PW Declare under our sole responsibility that the following product s Yale Model SR PIR EF PIR SR PETPIR EF PETPIR SR DC EF DC SR KF EF KF SR KP FE KP SR PB EF PB SR SD EF SD SR BX EF BX SR PC EF BXINT SR PVC EF PANEL SR PS EF IPBOX SR RS EF INTBOX SR SR EF Easy Fit Alarm Kits SR EIR SR SR SR WS SR CO SR HUB SR HUL SR HSL SR MZ8 SR Smart Home Alarm kits SR Standard Alarm kits S...

Отзывы: