Location planning

Work out the best places to locate the devices for maximum protection. Having chosen 
the locations 

do not mount at this stage

.

4

1

Keypad remote control accessory

When used as second keypad, it is ideal

in bedrooms or at the top of a stairwell so
the ground floor can be armed when going
to bed for the night. Or, at a side or back
door for alternative entry.
• Mount at chest height for ease of use
• Designed for indoor use only
• Keypad should be accessible from a

protected entry/exit point

• Ensure that the keypad is not visible from

the outside of the premises.

Home and away mode planning

The home arming mode allows the premises to

be part armed so that no one can get inside
without warning the occupier, yet the person
already inside the house can move freely without
triggering the alarm. For example the downstairs
of a house can be armed while upstairs can be
disarmed allowing the user to go to bed without
causing an alarm. 

If this feature is to be used, then it should

be planned now, before installation.

Decide what areas can be occupied when in

home arming mode, the sensors for these areas
should be programmed to home omit; and the
sensors activated on the path to access the
control unit should be to be set to home delay as
explained in ‘Further programming’ (page 16).

Operating range

All devices must be within 30 metres of the

control unit and must not be mounted on or near
large metal objects. Avoid obvious sources of
electrical interference such as fridges and
microwave ovens.

Tamper switches

When mounting devices ensure that any

tamper switches close fully. On uneven surfaces it
may be necessary to place packing behind the
switch for reliable operation.

Extend the system

Extend the system in the future to increase

your security or as your needs change.

For example, add extra PIR detectors and 

extra door/window contacts. 

Help button accessory

The help button provides extra protection

for you and your family. When help is needed
the button can activate your alarm
immediately - even when the system is
disarmed. 
• Mount on bedroom wall or by the front

door

• Not clearly visible to an intruder
• Easily accessible
• Out of reach of children

Dummy siren

Choose a secondary position on another

external wall where the siren would be most
prominent. Mount as high as possible, out of
easy reach.

Downloaded from www.ukpanels.com

Содержание HSA3800

Страница 1: ...A3800 Telecommunicating control panel alarm system Installation Programming Operating Keep in a handy place for reference and for future maintenance Helpline 01902 635998 Downloaded from www ukpanels com ...

Страница 2: ...re in the world This innovative feature allows the kind of flexibility and control we have come to expect in this day and age When accessed via telephone the system will only work with your PIN code It is important to ensure that you keep this number secure Home and away arming In addition to fully arming the system the HSA3800 also allows you to home arm The home mode allows you to arm the system...

Страница 3: ...es Carton contents Control unit and mounting base External siren Dummy siren 2 x PIR 2 x Door contact 2 x Door contact magnet 2 metre 500mA 9V power adaptor 3 metre telephone cable 2 way telephone adaptor 4 x 1 5V AAA alkaline cells 6 x 1 5V AA alkaline cells 4 x 1 5V D alkaline cells 2 x Large adhesive pad 2 x Small adhesive pad 4 x small wall plugs 12 x medium wall plugs 8 x large wall plugs 8 x...

Страница 4: ... arming mode the sensors for these areas should be programmed to home omit and the sensors activated on the path to access the control unit should be to be set to home delay as explained in Further programming page 16 Operating range All devices must be within 30 metres of the control unit and must not be mounted on or near large metal objects Avoid obvious sources of electrical interference such ...

Страница 5: ...directly facing a window Do not point the PIR at a door protected by a door window contact Keyfob remote control accessory Can be used inside or outside the property and can be kept on your keyring Door Window contact Select a door that will be the main point of entry and exit usually your front door Mount as high as possible Do not aim a PIR at this door or window Siren Choose a position on an ex...

Страница 6: ... all the parts onto a table top The easiest way to get to know the system and get it up and running quickly is to get all the devices and accessories programmed on a table top before locating and mounting them 2 Siren WARNING The siren is very loud be prepared Take care not to activate the siren unnecessarily 1 Remove the cover by unscrewing the single screw located at the bottom 2 Remove the cove...

Страница 7: ...as shown The Tx LED will flash briefly while components initialise Smoke detector accessory Remove the cover and insert the four AAA batteries as shown Keyfob remote control accessory Slide off the battery cover insert the 23A MN21 battery as shown and replace cover Switch to on Tamper switch Jumper switch Learn Test button Tamper switch Jumper switch Extension terminals Magnet Learn Test button L...

Страница 8: ...ic system up and running Do not mount at this stage Control unit When power is connected a long beep will sound Alarm On will be displayed This indicates that the system is armed Before you can deactivate the alarm or enter any information into the system you must enter a PIN code This is factory set to 0000 Disarm 1 Key 0 Enter Code is displayed 2 Key in 000 to complete the factory set code 3 Pre...

Страница 9: ...ompartment 1 Lift off jumper number 1 and park it The siren will beep and flash The siren is now in learn mode 2 Lift off jumper 5 and park it This must be left in the off position permanently If jumper 3 and jumper 4 are removed during the learning in process the siren will only be activated for 1 second if accidently activated and is useful for testing Ensure the jumpers are placed into the posi...

Страница 10: ...n for the programmed period If the tamper condition persists the siren will sound a series of five pips either every time the system is armed or when the tamper is enabled to indicate the condition Confirm Programming The siren can be programmed to produce additional confirmation beeps to tell you when the system is armed and disarmed from outside the premises One beep for armed or home armed two ...

Страница 11: ...y apply to the back of the device Next remove the other cover and firmly press the item onto the desired location Do not use the adhesive pad method of installation on a surface with peeling or cracked paint or on a rough surface Screw mounting Remove the front of the device and if necessary break through the appropriate knockout where the plastic is thinner Using the holes as a template drill hol...

Страница 12: ...tted at the same instant when entering cancelling each other out Ensure the jumper is in the normal off position when testing is finished otherwise low battery and tamper conditions will not be shown Door Window contact 1 Ensure the jumper switch is in the test on position In this position the indicator light will illuminate every time the door contact is operated 2 Fit as described in Mounting me...

Страница 13: ... the control unit will activate the alarm immediately irrespective of what armed mode the control unit is in During an alarm the control unit will sound the siren and start to dial the programmed phone numbers If a tamper alarm is activated when the panel is disarmed the system will not dial out Stopping the alarm 1 Key in your PIN code and then press OK The alarm and dialling will stop and the di...

Страница 14: ...sure the control unit is in Walk Test mode Low battery display When a detectors batteries are running low it will signal its condition to the control unit when it is activated To be able to clear the display the batteries in the detector will have to be changed Always use alkaline batteries as replacements and ensure the control unit is in Walk Test when taking down detectors After changing batter...

Страница 15: ...ult The exit sound can be selected for high or low volume Entry sound Switches on and off the entry countdown beeps 1 Press arrow keys to select the option 2 Press OK to confirm Entry Snd Low is set as factory default The entry sound can be selected for high or low volume Door chime Switches on and off the door chime in the control unit when an entry sensor is activated 1 Press arrow keys to selec...

Страница 16: ...mmence an entry countdown upon detection when the system is home armed but cause an instant alarm when fully armed To commence an entry countdown upon detection when the system is fully or home armed These choices are presented during the learning in process and are summarised by the following codes within the control unit B Burglar active when control unit is in armed or home mode O home Omit not...

Страница 17: ...nt if the detector has a tamper or low battery condition Multiple door window contact wiring If difficulty is experienced fitting the door window contact because of space etc the PIR sleep feature The PIR has a built in sleep timer to save battery power If there is no movement in front of the PIR for 1 minute the PIR will become ready to signal and movement will now be reported The PIR will sleep ...

Страница 18: ...y pressing the Disarm button again for 1 second When arming the system in home mode using the keyfob remote the system will arm and disarm instantly without an exit or entry countdown Keypad remote control accessory Programming 1 Enter the Devices menu and select the Add Device sub menu 2 When prompted by the control unit enter 0000 on the keypad then press TEST The Tx LED will flash showing that ...

Страница 19: ... to alarm The smoke detector will produce a warning beep and the LED will flash every 30 seconds if the batteries are near exhaustion The learn test button can be used to test the smoke detector With the control unit in walk test press the learn test button the detector will sound a two tone confirmation and the control unit will confirm Please ensure that you test smoke detectors regularly Remove...

Страница 20: ...A having the highest priority If a slot does not have a telephone number stored three dots are displayed indicating the slot is empty In the list only the first 9 digits of the telephone number are displayed Numbers longer than 9 digits are indicated with two dots after the digits displayed Storing telephone numbers 1 In the Tel Numbers menu the cursor will be flashing at location A 2 Press OK 3 E...

Страница 21: ...ter saying your address message press OK The display will then allow you to record your specific alarm messages At any time pressing a will abort recording and the message will not be stored The display will return to the menu The maximum length of the address message is 8 seconds When the 8 seconds are over recording will stop automatically and the message recorded will be stored When recording m...

Страница 22: ...s 0 on their phone set as the acknowledging signal the control unit will then take the following actions The control unit will go back offline The control unit will continue alarming The control unit will try to dial the next phone number s until two recipients have acknowledged the call Acknowledging with 9 key If the recipient presses 9 on their phone set as the acknowledging signal the followin...

Страница 23: ... phone number of the next priority until a total of 2 calls have been acknowledged Terminating with 9 key The two way voice communication will be terminated The control unit will go back offline The alarm will be silenced The control unit will stop dialling The control unit provides the convenience of functioning as a hands free phone You can dial the phone number on the keypad of the control unit...

Страница 24: ...re you hang up or the control unit will hang up automatically 30 seconds after except in the situation that the two way communication channel was opened by pressing 1 in this case the control unit will hang up 5 minutes after Hands free call answering If the system is in Disarmed mode or Home mode when the telephone rings you can answer the call without lifting a handset 1 When the telephone rings...

Страница 25: ...d the siren tamper must be disabled again by selecting Devices the selecting Program Siren menu and then Siren A T Off Press OK 3 Refit the siren cover 4 Enable the siren tamper by selecting Siren A T On in the Program Siren menu Press OK PIR and door window contact The LED will flash every time the device is activated indicating a low battery and the control unit display will identify the sensor ...

Страница 26: ...sticated false alarm filtering that will filter out random fluctuations and responds to genuine movement across field of view it is less sensitive walking directly towards it PIR gives false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR is not mounted above convector heaters or pointing d...

Страница 27: ...e receiver with jamming detection Power supply 6V 4 x D alkaline cells 3 years minimum typical service life PIR movement detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AA alkaline cells 3 years minimum typical domestic service life 1 minute sleep timer Movement detection rang...

Страница 28: ...r flash they have either been tampered with See trouble shooting page 26 or require a new battery See how to change a battery page 25 www yale co uk E mail info yaleuk com Security Products UK Ltd Wood Street Willenhall West Midlands WV13 1LA Yale is a registered trademark E2 11 03 Downloaded from www ukpanels com ...

Отзывы: