HSA3090 multiple door/window contact set
should be used (not included).

The magnet/contact pairs are wired using bell

wire (not supplied) to the extension terminals as
indicated on page 7. The knockout in the top of
the door/window contact must be removed to
allow the wire to pass through. The total length of
wire used must not exceed 10 metres. The
magnet/contact pairs should be no further than
8mm apart.

It is possible to use a single pair of multiple

door/window contacts with a detector if you
experience problems fitting the main unit to the
door frame.

When using multiple switches on a

door/window contact, you can use the detector
without having a magnet alongside the main unit.

17

Points for consideration

• In home mode, detectors set as ‘Burglar’ will

cause an alarm when activated, whilst
detectors set as ‘Home Omit’ will not trigger
an alarm.

• If the system is fully or home armed, detectors

set as ‘Entry’ will start the entry countdown
when activated. When disarmed, an entry
detector will sound a ‘ding-dong’ chime from
the control unit (if ‘door chime’ is selected).

• If a detector is set as ‘Home Delay’ it will start

an entry countdown when the system is home
armed. This setting is useful if your path to the
control unit (when used at night) is vulnerable
(a stairwell for instance).

• After testing the door/window contact and PIR

in your chosen locations, please ensure that
the jumpers are moved into the ‘off’ (parked)
positions. If left in the ‘on’ positions battery life
will be shortened and it will not be apparent if
the detector has a tamper or low battery
condition.

Multiple door/window contact wiring

If difficulty is experienced fitting the

door/window contact because of space etc, the

PIR sleep feature

The PIR has a built-in sleep timer to save

battery power. If there is no movement in front of
the PIR for 1 minute, the PIR will become ‘ready
to signal’ and movement will now be reported.
The PIR will sleep for 1 minute after. Any
movement detected in sleep time will not be
reported and will extend the sleep period by 1
minute.

Walk test

This allows you to test the system without

causing an alarm.

1

Press 

c

followed by your PIN code.

2

Press OK.

3

Select ‘Walk Test’.

4

Walk around protected areas in front of PIR’s
and open doors/windows protected by door
contacts. 

• If the control unit receives a signal, it will sound

a chime and the display will show the sensor
and zone number which has been tested.   

• The message will be displayed until being

replaced by another test signal.

• Pressing the 

a

key, will return to programming

menu.

• If left in walk test, the control unit will revert

back to ‘Alarm off’ after 20 minutes.

Testing the siren

The siren can be tested by arming and

disarming the system, the siren will respond as
follows:
• When the control unit is armed the siren will

beep once (if siren confirm is switched on) and
will flash after the Exit delay period has expired.

• When the control unit is disarmed, the siren will

give two short beeps (if siren confirm is
switched on) and will flash from side to side
twice.

Knockout
removed for
wire

Door/window
switches wired
in series

Magnets

Testing the system

Testing the system should be done on a regular basis and after any alterations.

Downloaded from www.ukpanels.com

Содержание HSA3800

Страница 1: ...A3800 Telecommunicating control panel alarm system Installation Programming Operating Keep in a handy place for reference and for future maintenance Helpline 01902 635998 Downloaded from www ukpanels com ...

Страница 2: ...re in the world This innovative feature allows the kind of flexibility and control we have come to expect in this day and age When accessed via telephone the system will only work with your PIN code It is important to ensure that you keep this number secure Home and away arming In addition to fully arming the system the HSA3800 also allows you to home arm The home mode allows you to arm the system...

Страница 3: ...es Carton contents Control unit and mounting base External siren Dummy siren 2 x PIR 2 x Door contact 2 x Door contact magnet 2 metre 500mA 9V power adaptor 3 metre telephone cable 2 way telephone adaptor 4 x 1 5V AAA alkaline cells 6 x 1 5V AA alkaline cells 4 x 1 5V D alkaline cells 2 x Large adhesive pad 2 x Small adhesive pad 4 x small wall plugs 12 x medium wall plugs 8 x large wall plugs 8 x...

Страница 4: ... arming mode the sensors for these areas should be programmed to home omit and the sensors activated on the path to access the control unit should be to be set to home delay as explained in Further programming page 16 Operating range All devices must be within 30 metres of the control unit and must not be mounted on or near large metal objects Avoid obvious sources of electrical interference such ...

Страница 5: ...directly facing a window Do not point the PIR at a door protected by a door window contact Keyfob remote control accessory Can be used inside or outside the property and can be kept on your keyring Door Window contact Select a door that will be the main point of entry and exit usually your front door Mount as high as possible Do not aim a PIR at this door or window Siren Choose a position on an ex...

Страница 6: ... all the parts onto a table top The easiest way to get to know the system and get it up and running quickly is to get all the devices and accessories programmed on a table top before locating and mounting them 2 Siren WARNING The siren is very loud be prepared Take care not to activate the siren unnecessarily 1 Remove the cover by unscrewing the single screw located at the bottom 2 Remove the cove...

Страница 7: ...as shown The Tx LED will flash briefly while components initialise Smoke detector accessory Remove the cover and insert the four AAA batteries as shown Keyfob remote control accessory Slide off the battery cover insert the 23A MN21 battery as shown and replace cover Switch to on Tamper switch Jumper switch Learn Test button Tamper switch Jumper switch Extension terminals Magnet Learn Test button L...

Страница 8: ...ic system up and running Do not mount at this stage Control unit When power is connected a long beep will sound Alarm On will be displayed This indicates that the system is armed Before you can deactivate the alarm or enter any information into the system you must enter a PIN code This is factory set to 0000 Disarm 1 Key 0 Enter Code is displayed 2 Key in 000 to complete the factory set code 3 Pre...

Страница 9: ...ompartment 1 Lift off jumper number 1 and park it The siren will beep and flash The siren is now in learn mode 2 Lift off jumper 5 and park it This must be left in the off position permanently If jumper 3 and jumper 4 are removed during the learning in process the siren will only be activated for 1 second if accidently activated and is useful for testing Ensure the jumpers are placed into the posi...

Страница 10: ...n for the programmed period If the tamper condition persists the siren will sound a series of five pips either every time the system is armed or when the tamper is enabled to indicate the condition Confirm Programming The siren can be programmed to produce additional confirmation beeps to tell you when the system is armed and disarmed from outside the premises One beep for armed or home armed two ...

Страница 11: ...y apply to the back of the device Next remove the other cover and firmly press the item onto the desired location Do not use the adhesive pad method of installation on a surface with peeling or cracked paint or on a rough surface Screw mounting Remove the front of the device and if necessary break through the appropriate knockout where the plastic is thinner Using the holes as a template drill hol...

Страница 12: ...tted at the same instant when entering cancelling each other out Ensure the jumper is in the normal off position when testing is finished otherwise low battery and tamper conditions will not be shown Door Window contact 1 Ensure the jumper switch is in the test on position In this position the indicator light will illuminate every time the door contact is operated 2 Fit as described in Mounting me...

Страница 13: ... the control unit will activate the alarm immediately irrespective of what armed mode the control unit is in During an alarm the control unit will sound the siren and start to dial the programmed phone numbers If a tamper alarm is activated when the panel is disarmed the system will not dial out Stopping the alarm 1 Key in your PIN code and then press OK The alarm and dialling will stop and the di...

Страница 14: ...sure the control unit is in Walk Test mode Low battery display When a detectors batteries are running low it will signal its condition to the control unit when it is activated To be able to clear the display the batteries in the detector will have to be changed Always use alkaline batteries as replacements and ensure the control unit is in Walk Test when taking down detectors After changing batter...

Страница 15: ...ult The exit sound can be selected for high or low volume Entry sound Switches on and off the entry countdown beeps 1 Press arrow keys to select the option 2 Press OK to confirm Entry Snd Low is set as factory default The entry sound can be selected for high or low volume Door chime Switches on and off the door chime in the control unit when an entry sensor is activated 1 Press arrow keys to selec...

Страница 16: ...mmence an entry countdown upon detection when the system is home armed but cause an instant alarm when fully armed To commence an entry countdown upon detection when the system is fully or home armed These choices are presented during the learning in process and are summarised by the following codes within the control unit B Burglar active when control unit is in armed or home mode O home Omit not...

Страница 17: ...nt if the detector has a tamper or low battery condition Multiple door window contact wiring If difficulty is experienced fitting the door window contact because of space etc the PIR sleep feature The PIR has a built in sleep timer to save battery power If there is no movement in front of the PIR for 1 minute the PIR will become ready to signal and movement will now be reported The PIR will sleep ...

Страница 18: ...y pressing the Disarm button again for 1 second When arming the system in home mode using the keyfob remote the system will arm and disarm instantly without an exit or entry countdown Keypad remote control accessory Programming 1 Enter the Devices menu and select the Add Device sub menu 2 When prompted by the control unit enter 0000 on the keypad then press TEST The Tx LED will flash showing that ...

Страница 19: ... to alarm The smoke detector will produce a warning beep and the LED will flash every 30 seconds if the batteries are near exhaustion The learn test button can be used to test the smoke detector With the control unit in walk test press the learn test button the detector will sound a two tone confirmation and the control unit will confirm Please ensure that you test smoke detectors regularly Remove...

Страница 20: ...A having the highest priority If a slot does not have a telephone number stored three dots are displayed indicating the slot is empty In the list only the first 9 digits of the telephone number are displayed Numbers longer than 9 digits are indicated with two dots after the digits displayed Storing telephone numbers 1 In the Tel Numbers menu the cursor will be flashing at location A 2 Press OK 3 E...

Страница 21: ...ter saying your address message press OK The display will then allow you to record your specific alarm messages At any time pressing a will abort recording and the message will not be stored The display will return to the menu The maximum length of the address message is 8 seconds When the 8 seconds are over recording will stop automatically and the message recorded will be stored When recording m...

Страница 22: ...s 0 on their phone set as the acknowledging signal the control unit will then take the following actions The control unit will go back offline The control unit will continue alarming The control unit will try to dial the next phone number s until two recipients have acknowledged the call Acknowledging with 9 key If the recipient presses 9 on their phone set as the acknowledging signal the followin...

Страница 23: ... phone number of the next priority until a total of 2 calls have been acknowledged Terminating with 9 key The two way voice communication will be terminated The control unit will go back offline The alarm will be silenced The control unit will stop dialling The control unit provides the convenience of functioning as a hands free phone You can dial the phone number on the keypad of the control unit...

Страница 24: ...re you hang up or the control unit will hang up automatically 30 seconds after except in the situation that the two way communication channel was opened by pressing 1 in this case the control unit will hang up 5 minutes after Hands free call answering If the system is in Disarmed mode or Home mode when the telephone rings you can answer the call without lifting a handset 1 When the telephone rings...

Страница 25: ...d the siren tamper must be disabled again by selecting Devices the selecting Program Siren menu and then Siren A T Off Press OK 3 Refit the siren cover 4 Enable the siren tamper by selecting Siren A T On in the Program Siren menu Press OK PIR and door window contact The LED will flash every time the device is activated indicating a low battery and the control unit display will identify the sensor ...

Страница 26: ...sticated false alarm filtering that will filter out random fluctuations and responds to genuine movement across field of view it is less sensitive walking directly towards it PIR gives false alarms Check pets have no access to protected area Check that PIR is not pointed at sources of heat or moving objects e g fluttering curtains Check that PIR is not mounted above convector heaters or pointing d...

Страница 27: ...e receiver with jamming detection Power supply 6V 4 x D alkaline cells 3 years minimum typical service life PIR movement detector Alarm processing Microprocessor controlled dual edge sequential pulse count with pulse length discrimination Radio 433 92MHz AM transmitter Power supply 4 5V 3 x AA alkaline cells 3 years minimum typical domestic service life 1 minute sleep timer Movement detection rang...

Страница 28: ...r flash they have either been tampered with See trouble shooting page 26 or require a new battery See how to change a battery page 25 www yale co uk E mail info yaleuk com Security Products UK Ltd Wood Street Willenhall West Midlands WV13 1LA Yale is a registered trademark E2 11 03 Downloaded from www ukpanels com ...

Отзывы: