VX-3R/E O
PERATING
M
ANUAL
55
S
CANNING
To set the Scan-Restart Delay Time:
1.
Press and hold in the [
TXPO
] key for one second to enter the Set mode.
2.
Rotate the
DIAL
knob to select Set Mode Item 76:
SCN.STR
.
Note
: Do not forget to pull the
DIAL
knob to rotate the
DIAL
knob.
3.
Press the [
TXPO
] key momentarily to enable adjustment of this
Set Mode Item.
4.
Rotate the
DIAL
knob to select the desired Scan-Restart Delay
Time. Available selections are
100
-
900 MS
(100 MS/step)
and
1
-
10 SEC
(0.5 SEC/step).
5.
When you have made your selection, press the
PTT
switch to save the new setting and
exit to normal operation.
The default condition for this Set Mode Item is “2 SEC.”