VX-3R/E O
PERATING
M
ANUAL
120
Set Mode Item 75
[
SCN.RSM
]
Function
: Selects the Scan Resume mode.
Available Values
: 2SEC - 10SEC/BUSY/HOLD
Default
: 5 SEC
2 SEC - 10 SEC: The scanner will halt on a signal it encounters, and will hold there for the
selected resume time. If you do not take action to disable the scanner
within that time period, the scanner will resume even if the station is still
active.
BUSY:
The scanner will halt on a signal it encounters. When the signal drops,
the scanner will resume. The Scan resume time (default 2 seconds) is
controlledset by the Set Mode Item 76:
SCN.STR
.
HOLD:
The scanner will halt on a signal it encounters. It will not restart auto-
matically; you must manually re-initiate scanning if you wish to resume.
Set Mode Item 76
[
SCN.STR
]
Function
: Select the Scan Re-start Delay time.
Available Values
: 0.1 - 0.4S (0.1S/step) or 1.0S - 10.0S (0.5S/step)
Default
: 2.0S
Set Mode Item 77
[
SP OUT
]
Function
: Enables/Disables the FM Broadcast audio output to the internal speaker when
using the earphone antenna.
Available Values
: AUTO/SPKR
Default
: AUTO
AUTO: The FM Broadcast audio output is selected automatically depending on the con-
nection of the earphone antenna.
SPKR: Outputs the FM Broadcast audio output to the internal speaker any time.
Set Mode Item 78
[
SQ LVL
]
Function
: Sets the Squelch threshold level.
Available Values
: LVL 0 - LVL 15 (AM and Narrow FM), LVL 0 - LVL 8 (Wide FM and
AM Broadcast)
Default
: LVL 1 (AM and Narrow FM), LVL 2 (Wide FM and AM Broadcast)