Page 122
FT
DX
5000 O
PERATING
M
ANUAL
013 DISP PK HLD
Function
: Selects the peak hold time of the VFO-B
receiver’s S-meter.
Available Values
: OFF / 0.5s / 1.0s / 2.0s
Default Setting
: OFF
014 DISP RTR STU
Function
: Selects the starting point of your rotator
controller’s indicator needle.
Available Values
: 0° / 90° / 180° / 270°
Default Setting
: 0°
015 DISP RTR ADJ
Function
: Adjusts the indicator needle precisely to the
starting point set in menu item “014 DISP RTR STU”.
Available Values
: –30° ~ 0° (2°/step)
Default Setting
: 0°
016 DISP QMB MKR
Function: Enables/Disables the QMB Marker (White ar-
row “
”) to display on the Spectrum Band Scope when
the optional
DMU-2000
Data Management Unit is con-
nected.
Available Values: DISABLE / ENABLE
Default Setting: ENABLE
A
DVICE
:
If the optional
DMU-2000
Data Management Unit is not
connected, this adjustment has no effect.
017 DISP LVL IND
Function
: Enables/Disables the Main Display to show the
frequency or value while each enabled knob is turned.
Available Values
: PTCH (PITCH) / SPED (SPEED) /
CDLY (CW DELAY) / VDLY (VOX DEALAY) / RPWR
(RF POWER) / MICG (MIC GAIN) / PROC (PROCES-
SOR GAIN)
To disable the “function,” rotate the (
VFO-B
)[
SELECT
]
knob to recall the “function” to be disabled, then press the
[
ENT
] key (one of the [
BAND
] buttons) to change this
setting to “OFF”. Repeat the same procedures to enable a
function (setting it to “ON”).
018 DISP INDI
Function
: Select the indicator location of the current value
when adjusting the following knobs
.
Available Values
: VFD / OEL
Default Setting
: VFD
VFD: The current value will show for 3-seconds in the
lower right corner of the Main Display when-
ever the following knob
is turned.
OEL: The current value will show for 3-seconds in the
SUB DISPLAY-
III
window whenever the fol-
lowing knob
is turned.
:
MIC
,
RF PWR
,
SPEED
,
PITCH
,
DELAY
, and
PITCH
knob
DISPLAY G
ROUP
019 DISP SELECT
Function
: Selects the display pattern of the
SUB DIS-
PLAY-
II
and
SUB DISPLAY-
III
windows.
Available Values
: PTN1 / PTN2 / PTN3
Default Setting
: PTN2
PTN1: Generally, the current value is not indicated in
the window, only the graphic is depicted. When
the [
SELECT
] knob is rotated, the current
value will appear under the graphical display.
Three seconds after the turning of the [
SE-
LECT
] knob is stopped, the current value in-
dication disappears.
PTN2: Generally, the current value is indicated with
the small characters and graphical display.
When the [
SELECT
] knob is rotated, the cur-
rent value indication becomes large characters.
Three seconds after the turning of the [
SE-
LECT
] knob is stopped, the current value in-
dication returns to small characters.
PTN3: The current value always indicated with the
large characters and graphical display.
M
ENU
M
ODE
DVS G
ROUP
020 DVS RX LVL
Function
: Sets the audio output level from the voice
memory.
Available Values
: 0 ~ 100
Default
: 50
021 DVS TX LVL
Function
: Sets the microphone input level to the voice
memory
Available Values
: 0 ~ 100
Default
: 50
PTN1
PTN2
PTN3
G
ENERAL
W
HILE
A
DJUSTING
SUB DISPLAY E
XAMPLES
(
CONTOUR O
PERATION
)
Содержание FTdx5000MP
Страница 7: ...Page 5 FTDX5000 OPERATING MANUAL NOTE...
Страница 13: ...Page 11 FTDX5000 OPERATING MANUAL CONNECTION OF MICROPHONE AND HEADPHONE INSTALLATION AND INTERCONNECTIONS...
Страница 59: ...Page 57 FTDX5000 OPERATING MANUAL INTERFERENCE REJECTION SIGNALS OFF FREQUENCY BY JUST A FEW KHZ NOTE...
Страница 115: ...Page 113 FTDX5000 OPERATING MANUAL NOTE...
Страница 139: ...Page 137 FTDX5000 OPERATING MANUAL MENU MODE NOTE...
Страница 143: ...Page 141 FTDX5000 OPERATING MANUAL NOTE...