Technical data
System 182-XT-4
9 - 4
ba76027e02
12/2014
Relay
(3 x)
Terminals
Cable glands
PROFIBUS connection
9-pin SUB-D socket on the top of the enclosure, compatible with
Phoenix connector (IP 67).
Output
Galvanically separated
Max. switching voltage
Front terminal strip:
240 VAC or 24 VDC
Rear terminal strip:
250 VAC or 24 VDC
Max. switching current
Front terminal strip:
2 A (AC and DC)
Rear terminal strip:
5 A (AC and DC)
Fuse rating on the
operator side
Front terminal strip:
max. 2 A
Rear terminal strip:
Maximum 5 A
Relay functions
Programmable as:
– Opener or closer
– Limit monitor
– Monitoring of the warning and error
signals of the DIQ/S 182-XT-4-PR
– Proportional frequency output
– Proportional pulse width output
Terminal type
Screw-type terminal strip, accessible by
opening the lid
Terminal ranges
Solid wires:
Flexible wires:
0.2 ... 4.0 mm
2
AWG 24 ... 12
0.2 ... 2.5 mm
2
Suitable for cable
diameter
4.5 ... 10 mm or 7 ... 13 mm
Содержание YSI 182-XT-4
Страница 6: ...Contents System 182 XT 4 0 4 ba76027e02 12 2014...
Страница 10: ...Overview System 182 XT 4 1 4 ba76027e02 12 2014...
Страница 14: ...Safety System 182 XT 4 2 4 ba76027e02 12 2014...
Страница 64: ...Installation System 182 XT 4 3 50 ba76027e02 12 2014...
Страница 82: ...Operation System 182 XT 4 4 18 ba76027e02 12 2014...
Страница 88: ...The SETTINGS menu System 182 XT 4 5 6 ba76027e02 12 2014...
Страница 114: ...Relay outputs System 182 XT 4 6 26 ba76027e02 12 2014...
Страница 116: ...Maintenance and cleaning System 182 XT 4 7 2 ba76027e02 12 2014...
Страница 122: ...What to do if System 182 XT 4 8 6 ba76027e02 12 2014...
Страница 134: ...Technical data System 182 XT 4 9 12 ba76027e02 12 2014...
Страница 135: ...System 182 XT 4 1 ba76027e02 12 2014...
Страница 138: ...Accessories and options System 182 XT 4 11 2 ba76027e02 12 2014...
Страница 142: ...Appendix store separately if required System 182 XT 4 13 2 ba76027e02 12 2014...
Страница 143: ......