SonTek, a Xylem brand
20
RiverSurveyor S5/M9 System Manual (February 2013)
(114.3mm). If the ADP head is mounted flush with the fairing, simply subtract the distance
of the white line to the waterline from 4.5 inches to get the transducer depth.
6. After the PCM and the ADP are in place, connect the data cable between them. Start by
connecting the cable’s 8-pin male connector to the female ADP connector until the face of
the cable is flush with the connector; now tighten the connection with the protective locking
sleeve. Next, repeat the same procedure to connect the data cable to the PCM. Connect
the 8-pin male cable connector by pushing the connector into the female connector em-
bedded in the PCM until the face of the cable is flush with the female connector; tighten the
connection with the protective locking sleeve.
Figure 20. An Assembled SonTek HydroBoard II (With RTK GPS Option)
7. GPS set-up information is in §3.5 and 3.6.
8. Attach the contoured hydro-fins to the bottom of the Hydroboard. Insert the fins into the
slots in the bottom of the Hydroboard with the contour facing the back of the Hydroboard.
Firmly tighten the fin to the board by sliding the screw through the small hole in the fin bot-
tom brace. Align the small metal screw clip (in a slide frame) under the hole and firmly
tighten the screw.
9. Turn on System Power by pressing the white circular button on top of the PCM. The button
should glow solid green.
10. Follow the instructions in Section 5 for completing a discharge measurement.