SonTek, a Xylem brand
RiverSurveyor S5/M9 System Manual (February 2013)
59
Figure 64. Compass Calibration Menu
At the end of calibration process, select
DONE
,
and a calibration score will be displayed as
shown in Figure 65, and will be saved to the SD memory card. Using the example below, the
calibration score is M6.20Q7. The M “value” should always be less than 10 and the Q “value”
should always be very high (based on a scale from 1-10). If the result is anything other than
“Pass” the process should be repeated.
Figure 65. Calibration Score
In the case that the SD memory card is not installed in the Mobile device, you will be notified.
The calibration can still be run, but will not be saved
.
7.6.5.
Download Recorder (5)
This menu displays the status of the recorder or memory of the ADP. The Download Recorder
menu (Figure 66) shows the recorder’s Total Space, Free Space, remaining capacity (as a per-
centage), and recorded file names and sizes. The file names use a four-digit year, two-digit
month, day, hour, minute, and second format (
YYYYMMDDHHMMSS
). All RiverSurveyor Live
files have an .riv extension. Within this menu, additional options are available through the
MENU
soft key. This submenu has the following options.
•
Download All Files
: Downloads all data files into the SD storage card on the Mobile device
(if no card, an error is displayed). A folder on the Mobile device is created named SonTek
Data. Gauging data is saved in a subfolder name based on the date/time recorded.
•
Download New Files
: Downloads all files which are not already on the storage card.