These parametrizing options are only available when the amount of energy is still <= 10 kWh.
Make sure that these
characteristics are set as needed before starting up the system.
Setup by pushing the button: In order to start the editing mode for parametrizing you must select the respective item in the
parametrizing loop and then push the button once again for 2-3 seconds. As an aid, after 2 seconds the „editing pen“ will be
displayed bottom left in the LCD (see below picture). As soon as it appears you have to let go of the button. Then the current
display will start blinking.
By pressing the push-button briefly you can switch to the next option. By pressing the push-button longer the currently
displayed option will be set. If no option is chosen there will be no change and as soon as the LCD goes out the edit mode will
end automatically.
b) The following characteristic of those calculator types designed to be used with glycol can be set on location
at any time
using the „Device Monitor“ software:
-
type and concentration of glycol in the medium
(propylene glycol; ethylene glycol; 20 %; 30 %; 40 %; 50%).
8.2
Detection of flow
As long as the calculator detects some flow the following pictogram will be displayed bottom right in the LCD:
flow detected
8.3
Volume pulses
When a volume pulse is received via the calculator input the following pictogram will be displayed bottom right in the LCD for 1
second:
volume pulse
9
Application Conditions
Calculator
Temperature range medium
heat
°C
0 – 150
Temperature range medium
cooling
°C
0 – 50
Mechanical class
M2
Electromagnetic class
E2
Protection class
IP54
Ambient temperature in the
field
°C
5 – 55 at 95 % relative humidity
Transport temperature
°C
-25 – 70 (for maximal 168 h)
Storage temperature
°C
-25 – 55
Pulse input interface
microcontroller CMOS input class IB according to EN 1434-2: 2015
Pulse values
standard
see type identification label
TX versions
adjustable pulse values will be shown in the display: 1; 2,5; 10; 25; 100;
250; 1000; 2500
Flow meter requirements
Pulse output device
class OA (reed contact) according to EN 1434-2: 2015;
class OC (open collector) according to EN 1434-2: 2015
Point of installation
outlet flow (standard) / inlet flow;
calculator can be set on location, only once, before start of operation by
pushing the button or alternatively using the „Device Monitor“ software
Maximum input frequency
Hz
10
Pulse length
ms
≥ 25
Pulse pause
ms
≥ 50
Temperature sensor requirements
Platinum precision resistor
Pt 500
Cable length (unshielded)
m
up to 10 in 2-wire technique