23
z
End:
To set the ending position. Set it in the same way as Start.
z
Speed:
Sets the panning speed (Dome movement speed). Value ranges from 001 to 255, the higher value represents the
higher speed. Pan right to select, tilt up or down to change value.
z
Show:
To run the current panning once, use this function to check the panning
z
Run:
To run the panning continuously.
5.7.5 Region Setup
System Menu > Auto Running Setup > Region Setup
A region is an area between two sites. User can assign a title for a REGION. (E.g. Dangerous area). Whenever the camera moves
into the region, the title will display on the screen to alert the user.
z
Number:
Displays the current region number. Values ranges from 001~008. Pan right then tilt up or down to select another
region.
z
Title:
Set the region title.
z
Setup:
Move to the desired position and call preset 1 to save left limit or call preset 2 to cancel. After setting the left limit,
below menu will pop-up, set the right limit as the same way as setting left limit
z
State:
Indicate the current region is existing or empty
z
Delete:
Delete current region.
5.7.6 Idle Time Setup
System Menu > Auto Running Setup > Idle Time Setup
This function let the system automatically run assigned function after the idle time. For example: the dome is running a sequence
and an operator breaks the sequence to do other work, the dome can automatically carry on the sequence within a period of
time after the operator finishes using it.
z
Idle Time
: It is a specific time without any operation being performed. The values include: Off, 003s~255s (seconds).
Region Setup
1. Number
:001
2. Title
:Region1
3. Setup
4: State
Empty
5. Delete
0. Back
Idle Time Setup
Idle Time
:30s
Call Preset 1 :Left Limit
Call Preset 2 Cancel
Call Preset 1 :Right Limit
Call Preset 2 Cancel