ADPRO
Network I/O Units – Technical Manual
33355_00
7
1
About the Network I/O Units
Note
You can find the latest versions of this document and any referenced document on the Xtralis Security
Solutions Support site
(logon may be required). If a document number is
indicated (between parentheses), you can enter it in the Keywords box on the site, and search for the
document.
1.1
Features
The Network (Net) I/O units are modules with LED indicators, contact inputs and relay outputs, controlled by an
ADPRO NVR+ device. The Net I/O units are compatible with the following device types:
l
ADPRO FastTrace 2 Series: FastTrace 2, FastTrace 2X, and FastTrace 2E
l
ADPRO iFT Series: iFT and iFT-E
l
ADPRO iFT Gateway
l
ADPRO V3100
1
.
The host system controls the Net I/O units through the Ethernet network (10 Mbps network only).
The base unit offers:
l
4 monitored or unmonitored inputs for voltage-free contacts. The possible states are:
o
idle
o
alarm
o
tamper short circuit (monitored inputs only)
o
tamper open circuit (monitored inputs only).
l
4 relay outputs (voltage-free switchover contacts) with status LED.
l
3 LED indicators for the system status of the controlling ADPRO NVR+ device:
o
red = recording
o
yellow = fault
o
green = power supply.
The base unit is:
l
mounted on a DIN rail
l
extendible with one to three extension units. Extension units are powered from the base unit. Each extension
unit offers:
o
4 monitored or unmonitored inputs
o
4 relay outputs.
l
powered by a local adapter (12 VDC; min. 350 mA) or by a PoE
2
switch or injector.
Base unit:
Extension unit:
1
On the V3100, the inputs always function as unmonitored inputs; monitored inputs are not possible.
2
PoE = Power over Ethernet