SeaAir Regulator
8
SeaAir Regulator Service and Repair Manual
Disassembly Procedures
General Guidelines
▼
Prior to performing any disassembly, check to ensure that the
service facility is well equipped with all the tools and parts need-
ed to perform a complete service from start to finish. DO NOT
attempt to perform the service unless all of the required tools
and parts are available.
▼
All o-rings are classified as being either dynamic or static.
Dynamic
o-rings are those which sustain friction and move-
ment, as they are either mounted directly onto a moving part,
or create a seal against a moving part.
Static
o-rings simply
create a seal between two non-moving parts, and are therefore
less subject to wear than dynamic o-rings. After passing close
inspection, static
O-rings may sometimes be reused, although this is not neces-
sarily recommended. Dynamic O-rings must be automatically
discarded and replaced with every service, regardless of age or
appearance.
▼
Refer to the schematic and parts list while performing these
procedures. Each part is identified by its reference number
shown on the drawing the first time it is referred to in the proce-
dure.
▼
Do not attempt to reuse parts that are designated to be auto-
matically discarded and replaced with the parts provided in the
overhaul parts kit. These parts should be shown to the cus-
tomer, however, to ensure their confidence and satisfaction that
complete overhaul service has been performed.
▼
Inspect all reusable parts as directed, either during or imme-
diately following the disassembly procedures. When in doubt,
compare the part with one that is new to best determine its
condition.
3
SECTI
O
N
Содержание SEAAIR
Страница 1: ...Service Repair Manual SERVICE AND REPAIR MANUAL SEAAIR REGULATOR PN RG200 Revised 02 11...
Страница 30: ......
Страница 31: ......