Service & Repair Manual
29
Copyright ©2015 XS Scuba
1. Excessive intermediate pressure.
1. Refer to first stage troubleshooting
2. Damaged or worn LP seat.
2. Replace with new.
3. Damaged orifice sealing surface.
3. Replace with new.
4. Damaged orifice O-ring.
4. Replace with new.
5. Orifice incorrectly adjusted.
5. Reset to preliminary setting and
readjust.
6. Poppet spring damaged.
6. Replace with new.
7. Lever pad is damaged or incorrectly
7. Replace with new.
installed.
1. Insufficent intermediate pressure.
1. Refer to first stage troubleshooting
2. Orifice incorrectly adjusted.
3. Reset to preliminary setting and
readjust.
3. Lever is damaged.
3. Replace with new.
1. Lever is slack, or orifice incorrectly adjusted. 1. Reset to preliminary settings and
readjust.
2. Lever is bent.
2. Replace with new.
1. Exhaust valve worn or damaged.
1. Replace with new.
2. Mouthpiece worn or damaged.
2. Replace with new.
3. Adjustment knob or O-ring damaged,
3. Disassemble and inspect, replace or
incorrectly installed, or worn.
reassemble as required.
Symptom
poSSible CauSe
treatment
Freeflow or leakage
(Adjustment knob turned in)
Excessive Inhalation Resistance
or Hesitation
(Adjustment knob turned out)
Insufficient airflow when
purge button is depressed
Troubleshooting Guide
Second Stage
Water entering second stage