Service & Repair Manual
15
Copyright ©2015 XS Scuba
the orifice head. Discard the O-ring and do not reuse.
19. Closely examine the orifice with the use of a magnifier, check-
ing for any scratches or other damage to the sealing edge and
the groove that holds the O-ring (see Fig. 14). If any damage or
wear is found, discard the orifice and do not attempt to reuse. If
it is in reusable condition, set it aside on a soft surface to keep it
isolated from other metal parts.
20. Remove the exhaust deflector(24) from the second stage hous-
ing to expose the exhaust valve(22) for inspection.
NOTE:
To facillitate the removal of the exhaust deflector,
first place it in hot (120°-150°F) water for 2-3 minutes and
allow it to soften.
21. Closely inspect the exhaust deflector to check for any signs of
damage that may have been caused by abuse or improper disas-
sembly. If found, discard it and replace with new.
22. Closely inspect the condition of the exhaust valve to ensure that
it is evenly seated against the second stage housing on all sides,
and free of any tears, holes, or other signs of decay. Peel back
the lip on all sides to ensure it is supple and returns to its origi-
nal position. If any wear or damage is detected, or if the mate-
rial feels stiff or decayed, pull the exhaust valve straight out of
the housing and discard it.
NOTE:
It is not necessary to remove the exhaust valve
diaphragm unless it shows signs of wear or decay upon in-
spection. Once the diaphragm is removed, however, it will be
permanently stretched and then must be replaced with new.
▼
After completing the disassembly of the first and
second stages, refer to the instructions provided in
the XS Scuba Authorized Service Document, titled -
Regulator Parts Cleaning Procedures.
Fig. 14 – Orifice Inspection
Fig. 13 – Removal of Adjustable Orifice
Содержание SEAAIR
Страница 1: ...Service Repair Manual SERVICE AND REPAIR MANUAL SEAAIR REGULATOR PN RG200 Revised 02 11...
Страница 30: ......