265 Prado Road, Suite 1 | San Luis Obispo, CA 93401 | 805.541.0100 | xpressfill.com | [email protected]
18
| XpressFill Systems LLC
Fluid Solenoid Valve Deep-Cleaning Instructions
Note:
This maintenance is needed only when the filler is not performing properly.
Remove the solenoid valve from the filler. Use the
release tool provided to disconnect the push-to-connect
fittings. If you disconnect the two wires, it does not
matter which wire goes back into which terminal.
Loosen the hex nut at the top of the coil assembly.
Unscrew the base from the coil assembly. Use a
screwdriver as needed. Remove the center shaft. Note
and keep track of the flat O-ring. A pair of pliers may
be needed to grip the metal shaft to “crack” open for
unscrewing the shaft.
Now clean out all openings inside and outside of the
solenoid
valve,
removing
any
particulates
and
stickiness that may have accumulated.
Reassemble and replace in the filler.
The white plastic body is marked #1 for output and
#2 for input. The valve may leak if
installed back-
wards.