1. Flip the Fill/Flush switch to flush mode (Rocker
switch located on left side of filler).
2. Place bottles under spouts.
3. Turn on the main power switch (Green rocker
switch located on right panel of the filler).
4. Turn on spout switch, full on position, all the way
up. Turn on the Pressure Release Switch (UP) to
allow flushing through the vent flow path.
5. Let solution fill the bottle completely and allow it to
run for a while after full.
6. Turn the spout switch to the middle position (stop
fill).
7. Turn on the spout switch again all the way up (This
runs the purge cycle again and allows the CO2
flow path to be cleaned as well). Repeat step 6 &7
a few times.
8. When satisfied with the cleaning process, put the
Fill/Flush switch back to Fill mode (DOWN).
9. Turn off the Fill Switch completely (DOWN). This
will allow you to remove the bottle and empty it of
the remaining cleaning solution. Also, turn off the
Pressure Release Switch (DOWN).
10. This is the end of part one of the two-part process
for cleaning your filler.
265 Prado Road, Suite 1 | San Luis Obispo, CA 93401 | 805.541.0100 | xpressfill.com | [email protected]
14
| XpressFill Systems LLC
Part One
Attach cleaning hoses as pictured below. Hosing and connectors are supplied in the accessory packet.