PROGRAMMING FLOWCHART
Validation OK?
No
Yes
Enter “Master Code”
B + 000000
Error Beep
(3 short beeps)
1 small beep + 1 long beep + Orange LED is ‘ON’
Press
“A”
to validate
and exit the menu
(orange LED OFF)
Change
Master Code
1
Enter New
Master Code
Press 6 Digits
2
Select Type of Wiegand
1
Wiegand
26bit
2
3
4
Wiegand
30bit
Wiegand
34bit
Wiegand
40bit
3
Select Output Protocol
1
2
3
4
Single
Wiegand
Double
Wiegand
Clock &
Data
Codix
PIN Code Length
4
0
1 - 8
for any length
with “A”
in the end
for lengths
between
1 to 8 digits
6
Presets
1
2
3
4
5
Wiegand
26bit
normal
Codix
Wiegand
34bit
normal
Wiegand
34bit
EWS
Wiegand
26bit
EWS
7
Site Code Length
1
2
3
4
No Site
Code
Site Code
between
0 to 15
Site Code
between
0 to 255
Site Code
between
0 to 65535
Enter Site
Code
8
5 digits
Backlight
9
0
1
Backlight
OFF
Backlight
ON
Direct Menu
exit
Entering Menu is always done with B + 000000 if the Master Code is not changed.
Submenu 1
-
Change Master Code
. The Master Code must be 6 digits. After enrolling new Master Code the MTPAD-M automatically exits
the Menu and the new master code must be typed to enter the menu.
Submenu 2
-
Select Type of Wiegand.
With this the Keypad can be adjusted to send 4 different Wiegand Outputs. The Wiegand selected
must be the same as the controller’s Wiegand Input where the MTPAD-M Keypad is being connected. Example: If you use a controller that
recognizes Wiegand 34bit, then enter the menu of MTPAD-M, press 2, then press 3.
Submenu 3
-
Select Output Protocol
. The Keypad can send the Code by different Protocols. Use “Single Wiegand” when connected to third
party controllers. When “Single Wiegand” is selected, what is typed on the Keypad the same will be sent as Wiegand Number. Use Double
Wiegand when connected to EWS, use Clock&Data when connected to controller with Clock&Data input, use Codix when connected to Vi200,
EX5, EX7, INOX99 or VKP99.
Submenu 4
-
PIN Code Length.
If “0” is selected, then any PIN Code with any length can be sent, but the PIN Code is typed with “A” for
confirmation( ex. 123 + A). If 1 to 8 is selected the PIN Code length is determinated by the number selected.
Submenu 6
-
Presets
.
The Presets are set of preprogrammed parameters for easy programming.
6-1
“Wiegand 26bit Normal” -
Type: Wiegand 26bit; Output: Single Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
6-2
“Wiegand 34bit Normal” -
Type: Wiegand 34bit; Output: Single Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
6-3
“Wiegand 34bit EWS Mode” - Type: Wiegand 34bit; Output: Double Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
6-4
“Wiegand 26bit EWS Mode” - Type: Wiegand 26bit; Output: Double Wiegand; PIN Length: 4 digits; Entry Mode: Card or PIN Code
6-5
“Codix” -
Output: Codix; PIN Length: any length with “A” in the end; Entry Mode: Card or PIN Code
Presets 6-3 and 6-4 to be used always when MTPAD-M is connected to EWS firmware ver.2.42 or higher.
Submenu 7 - Site Code Length.
S
. Defaul is “0”. To be used only in specific cases.
et the code length sent to Host
Submenu 8 - Enter Site Code.
Put the site code always in 5 digit format (ex. 00170).
Submenu 9 - Backlight.
Turns ON/OFF the backlight.
www.xprgroup.com
MTPAD-M