XO FLEX – Installation instructions
Installation
25
8.
Place a spirit level on top of the bridge arm post in the longitudinal direction – (A) in Figure
19 – see Figure 20.
9.
Turn the adjustment nut – (2) in Figure 19 – until the post is plumb in the longitudinal
direction and then tighten the nut on top of the long rod.
10.
Turn the spirit level to adjust the unit stand in the cross-wise direction – (B) in Figure 19 –
see Figure 21.
11.
Turn the adjustment nut – (4) in Figure 19 – counter-clockwise and make sure it does not
contact the bushing in the floor.
12.
Turn the adjustment nut – (3) in Figure 19 – until the bridge arm post is horizontal in the
crosswise direction and tighten the nut on top of the long rod.
13.
Turn the adjustment nut – (4) in Figure 19 – clockwise until it contacts the bushing in the
floor and tighten the nut on top of the long rod.
14.
Turn the adjustment nut – (1) in Figure 19– clockwise until it contacts the bushing in the
floor and tighten the nut on top of the long rod.
5.3
FITTING THE BRIDGE ARM AND INSTRUMENT BRIDGE
If the unit has been stocked/transported at a temperature of less than 10
o
C for more
than one hour, it needs to acquire room temperature before being connected to the
mains supply.
1.
Fit the bridge arm carefully by lowering it onto the bridge arm post; be careful not to tilt the arm
and squeeze the bearings – see Figure 26.
2.
Route the tubing and cables inside the outer cylinder as shown in Figure 27.
3.
Route the tubing to the water/air side of the unit stand and conduct the cables to the
electronics section.
4.
Fasten cables and tubing with cable ties to the cable holders.
5.
Check that cables and tubing move freely while the rear bridge arm rotates in its full range.
Figure 26 – Fitting the instrument bridge arm