XD9010-TS Rev D 07/2008
16
Installation & Operation Manual
Oven
Natural Gas
Main
Orifice ID
Pilot
Orifice ID
Pilot
Pressure
Manifold
Pressure
1832-TS/TS2
0.140"
2440-TS/TS2
0.156"
3240-TS/TS2
0.182"
3255-TS/TS2
0.234"
3270-TS/TS2
0.173"
3870-TS/TS2
0.173"
0.018”
3.5” WC
3.5" WC
GAS ORIFICE SIZES (per oven)
Oven
Propane Gas
Main
Orifice ID
Pilot
Orifice ID
Pilot
Pressure
Manifold
Pressure
1832-TS/TS2
0.156"
2440-TS/TS2
0.096"
3240-TS/TS2
0.110"
3255-TS/TS2
0.144"
3270-TS/TS2
0.104"
3870-TS/TS2
0.104"
0.018”
5.5” WC
10.0" WC
NOTE: For proper operation, measure the gas pressure, (see Figure 12), with all gas appliances,
such as furnace, hot water heater, oven(s), etc.,
a)
off and
b
) with all gas appliances
on
.
Figure 12: Gas Pressure Check
Contact BOFI, a factory representative, or a local service company to make all gas pressure