XD9010-TS Rev D 7/2008
Installation & Operation Manual
19
5.7. CASTERS
Because the oven(s) are equipped with casters, the installation must be made with a
connector that complies with the Standard for Connectors for Moveable Gas Appliances,
ANSI Z21.69 or Connectors for Moveable Gas Appliances CAN/CGA-6.16, and a
quick-disconnect device that complies with the Standard for Quick-Disconnect Devices
for Use With Gas Fuel, ANSI Z21.41, or Quick-Disconnect Devices for Use With Gas
Fuel, CAN1-6.9.
5.8. RESTRAINT
For all installations, a restraint must be provided to limit the movement of the oven
without depending on the gas connector and the quick-disconnect device or its
associated piping, and/or the electric cord, to limit the oven movement. The restraint
must be connected to the eye bolt which is supplied with the oven. The eye bolt is in the
lowest hole in the back wall on the control end of the oven. Upon completion of
performing any service functions that require removal of the restraint, insure that it is
correctly re-attached to the oven (see Figure 15).
One restraint is
required per oven
stack.
Figure 13: Restraint view
5.9. VENTILATION
5.9.1. VENTILATION REQUIREMENTS
Most gas burning appliances produce carbon monoxide, a poison. This and the heat
generated must be vented to the outside. A ventilation hood is required to remove the
heat and products of combustion. The hood and HVAC installation must meet local
building and mechanical codes. Requirements vary throughout the country depending