5.4. PHYSICAL LOCATION & SPACING REQUIREMENTS
It is best to install ovens adjacent to a wall. It is possible to install an oven in the middle
of a room, but due to the routing of gas and electric lines, and ventilation hood
performance, these installations can be more costly. The utility rough-in information is
shown on page 27.
These ovens are suitable for installation on combustible floors. The minimum clearance
from the back is 6" and is determined by the back wall standoffs that are included with
the oven. The standoffs are intended for use with either combustible or noncombustible
walls. The minimum side clearances are 6". See Section 7. Rough-In for gas and
electrical connections.
5.5. ELECTRICAL SUPPLY
All XLT ovens require a 120VAC power supply. See General Specifications Chart for
the electrical power requirements.
WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from this plug.
When installed, the appliance must be electrically grounded in accordance with local
codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA
70, or the Canadian Electrical Code, CSA C22.2, as applicable.
5.6. GAS SUPPLY
The gas supply shall have a gas meter and regulator large enough to handle all of the gas
appliances, such as the furnace, hot water heater, and oven(s), in operation at the same
time. Add up all of the Btu ratings to determine the total load.
The installation must conform with local building codes, or in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1, latest version, Natural Gas
Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-
B149.2, as applicable, including:
1.
The appliance and its individual shutoff valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures
in excess of ½-psi (3.45-kPa).
2.
The appliance must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than ½-psi (3.45-kPa).