Note: for example, /S-ON signal address 0x0800=1, this function is effective; 0x0800=0, this function
is ineffective.
Output state signal (can read, cannot write)
Item
Modbus
address
Item
Modbus
address
Positioning finished (/COIN)
0x0812
Brake lock ( /BK)
0x0818
Coincidence speed checking
(/V-CMP)
0x0813
Warn (/WARN)
0x0819
Rotation checking (/TGON)
0x0814
Near (/NEAR)
0x081A
Ready (/S-RDY)
0x0815
Alarm output (/ALM)
0x081B
Torque limit (/CLT)
0x0816
Encoder Z signal (/Z)
0x081C
Speed limit checking (/VLT)
0x0817
Appendix 2 Application
Mode 6: pulse command position mode
Equipment introduction:
This is a welder. Workpiece 1, 2, 3 are the object to be operated. 2 and 3 is fixed on B and A
individually. A and B can whole move and be pushed by ball screw E and F. The screw pitch is 5mm.
C and D is servo motor. G and H is reducer. The deceleration ratio is 40.
It needs to adjust the machine with standard dimension workpiece and find the origin of A and B.
Workpiece 1 lies on the worktable and moves left and right. Its dimension is positive tolerance, cannot
shorter than standard workpiece. The process to put the workpiece is random. It requires that the left
and right soldering is symmetrical.
A and B move toward 1 with 3 and 2 at the same speed. Whatever the position of 1, 2 or 3 will touch 1
at first and push 1 to another side until 2 and 3 all touch 1. The result is the motor torque will increase.
At this time, 1 will at the symmetrical position.
A and B will return to the origin position after soldering is finished.
Analysis
1.
Make sure the work mode: 6
2. It needs to judge whether 2 and 3 touch 1 when finding the symmetrical point. The sign is servo
output torque will increase. It needs to use torque limit (P4-02, P4-03) and torque limit output signal
/CLT.
3. As the dimension of workpiece is larger than standard, offset pulse will remain in servo when the
symmetrical point is found. /CLR signal can clear the pulse. The servo motor running distance is
different from PLC pulse number. If it needs to know the actual distance, servo encoder feedback
/A+, /A-, /B+, /B- and AB phase count are needed.
4. The motion direction of A and B.
Signal and terminal
/COIN positioning finished signal: SO1
/CLT torque up to upper limit output: SO2
/CLR pulse offset clear input: SI1
1
2
3
A
B
E
F
G
H
D
C