Circuit Description
WorkCentre Pro 412, FaxCentre F12 &
3/03
5-73
WorkCentre M15/M15i
5-10-6-3 The Concept of Fixed Lamp Control (WorkCentre Pro 412 & FaxCentre F12)
For fixed lamp control, the logic unit “fuser on” control signal and SMPS unit DC power must be supplied.
This circuit turns on only when “fuser on” sends the signal and the DC power is supplied.
The following explains how the fixed lamp control circuit works.
Logic unit “fuser on” sends trigger current to triac driver U501 LED, then the infrared ray is detected by
U501 photo detector. Next, U501 triac is conducted.
The conducted current sends trigger input to triac THY501 gate. At this point, THY501 is conducted and
AC power is supplied to fixed lamp. Lamp is turned on and temperature rises.
As this fixed lamp control circuit uses the AC voltage (“+” and “-” are repeated) as the power supply, it used
two-way triac (THY501), which has advantage over one-way SCR considering the price, size and reliabil-
ity.
Triac's gate can be triggered by either forward or reverse signal. Once triac is turned on, it will not be con-
trolled by gate signal, but will be continuously on until the current between major terminals decreases
below the holding current. In other words, you cannot turn it off with reverse signal unlike SCR. This prop-
erty is called current-voltage threshold rise rate (commutation: dv/dt). In AC power control application, triac
has to turn off conduction in each zero crossing or switch it twice in each cycle. This switching operation is
called commutation. It is possible to turn off the triac at the end of half cycle by eliminating the gate signal
when the load current (IL) is gained at the level equal to or lower than holding current. When triac com-
mutes off-line, the direction of the voltage of the both ends of triac will be reversed and increase up to the
maximum value of line voltage (VAC). At this point, the width of rise rate will be determined by dv/dt and
overshoot voltage, by the circuit. When triac commutes off-line, the voltage of both ends of triac will have
the same voltage as the line voltage.
Inductive Circuit
Содержание FaxCentre F12
Страница 8: ...Table of Contents TOC 6 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Страница 26: ...Precautions 3 2 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i This page is intentionally blank ...
Страница 44: ...Circuit Description 5 6 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Страница 45: ...Circuit Description WorkCentre Pro 412 FaxCentre F12 3 03 5 7 WorkCentre M15 M15i ...
Страница 46: ...Circuit Description 5 8 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Страница 47: ...Circuit Description WorkCentre Pro 412 FaxCentre F12 3 03 5 9 WorkCentre M15 M15i ...
Страница 48: ...Circuit Description 5 10 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Страница 49: ...Circuit Description WorkCentre Pro 412 FaxCentre F12 3 03 5 11 WorkCentre M15 M15i ...
Страница 50: ...Circuit Description 5 12 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Страница 80: ...Circuit Description 5 42 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i DUOIP2 Block Diagram ...
Страница 100: ...Circuit Description 5 62 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i MHV Output unit Block Diagram ...
Страница 170: ...Disassembly and Reassembly 6 58 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Страница 188: ...Maintenance Troubleshooting 7 18 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i No Image Part 1 ...
Страница 189: ...Maintenance Troubleshooting WorkCentre Pro 412 FaxCentre F12 3 03 7 19 WorkCentre M15 M15i No Image Part 2 ...
Страница 190: ...Maintenance Troubleshooting 7 20 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i All Black ...
Страница 191: ...Maintenance Troubleshooting WorkCentre Pro 412 FaxCentre F12 3 03 7 21 WorkCentre M15 M15i Vertical White LIne Band ...
Страница 192: ...Maintenance Troubleshooting 7 22 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i Dark Image ...
Страница 193: ...Maintenance Troubleshooting WorkCentre Pro 412 FaxCentre F12 3 03 7 23 WorkCentre M15 M15i Background ...
Страница 194: ...Maintenance Troubleshooting 7 24 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i Ghost ...
Страница 195: ...Maintenance Troubleshooting WorkCentre Pro 412 FaxCentre F12 3 03 7 25 WorkCentre M15 M15i Black Spot ...
Страница 196: ...Maintenance Troubleshooting 7 26 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i Horizontal Band ...
Страница 197: ...Maintenance Troubleshooting WorkCentre Pro 412 FaxCentre F12 3 03 7 27 WorkCentre M15 M15i Irregular Density ...
Страница 198: ...Maintenance Troubleshooting 7 28 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i White Spot ...
Страница 200: ...Maintenance Troubleshooting 7 30 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i Poor Fusing ...
Страница 203: ...Maintenance Troubleshooting WorkCentre Pro 412 FaxCentre F12 3 03 7 33 WorkCentre M15 M15i No Power No LCD or LEDs ...
Страница 204: ...Maintenance Troubleshooting 7 34 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i Fuser Error ...
Страница 205: ...Maintenance Troubleshooting WorkCentre Pro 412 FaxCentre F12 3 03 7 35 WorkCentre M15 M15i Paper Jam Mis feeding ...
Страница 206: ...Maintenance Troubleshooting 7 36 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i Paper Jam Jam 1 ...
Страница 226: ...Exploded View Parts List 8 4 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i This page intentionally blank ...
Страница 230: ...Exploded View Parts List 8 8 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i This page intentionally blank ...
Страница 234: ...Exploded View Parts List 8 12 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i This page intentionally blank ...
Страница 238: ...Exploded View Parts List 8 16 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i This page intentionally blank ...
Страница 266: ...Exploded View Parts List 8 44 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i This page intentionally blank ...
Страница 278: ...Exploded View Parts List 8 56 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i This page intentionally blank ...
Страница 292: ...Block Diagram WorkCentre M15 M15i 9 4 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Страница 296: ...Connection Diagram WorkCentre M15 M15i 10 4 3 03 WorkCentre Pro 412 FaxCentre F12 WorkCentre M15 M15i ...
Страница 380: ...XEROX EUROPE ...