STATUS INDICATOR RAPs
2/99
E4
2-6
DocuPrint C55/C55mp/[NC60]
E4 INPUT JAM RAP
Paper was on the Registration Sensor too
long.
INITIAL ACTION
Open the printer and check for any obstruction
in the register roller area.
Switch the power off wait 10 seconds and
switch the power on. Run another print to
recheck for the fault.
Make sure the Grounding Roller is rotating
freely.
Perform the Transfer Drum Nip Adjustment
(ADJ 11.1)
PROCEDURE
Enter IOT normal diagnostics. Scroll to the
SWITCH SCAN program and select Scan Row
00. Press
Form Feed [1]
.
Open the Printer. Actuate and deactuate the
Registration Sensor while observing the
Magenta LED.
The Magenta LED switches on and off.
Y
N
Go to BSD 8.1 in Section 7 and trouble-
shoot the Registration Sensor signal
(CN102-9) for a short to ground.
If no short exists, replace the PCU PWB.
If the problem still exists, replace the
Registration Sensor.
Press
Media Server [2]
. Select Scan Row 04.
Press
Form Feed [1]
.
Actuate and deactuate the Transparency
Sensor while observing the Cyan LED.
A
A
The Cyan LED switches on and off.
Y
N
Go to BSD 8.4 in Section 7 and trouble-
shoot the Transparency Sensor signal
(CN311-1) for a short to ground.
If no short exists, replace the PCU PWB.
If the problem still exists, replace the
Transparency Sensor.
Exit from the SWITCH SCAN program.
Close the Printer.
Remove the paper cassette. Scroll to the
MOTOR TEST program and press
Form Feed
[1]
to switch on the motors while observing the
Paper Feed Motor.
The Paper Feed Motor is rotating normally.
Y
N
Go to BSD 7.3 in Section 7 and trouble-
shoot the Paper Feed Motor clock lines.
If the lines are OK, replace the PCU PWB.
If the problem still exists, replace the
Paper Feed Motor.
Exit from diagnostics.
Set up the meter to read +24 VDC. Measure
between CN103-4 (+) and ground (
−
).
Make one print while monitoring the meter.
The meter swings from +24 VDC to 0 and
back to +24.
Y
N
Go to BSD 9.16 in Section 7 and trouble-
shoot the Stripper Solenoid signal and +24
VDC Interlocked (CN103-4, CN303-2,1) for
an open.
If no open exists, replace the PCU PWB. If
the problem still exists, replace the
Stripper Solenoid.
B
B
Set up the meter to read +24 VDC. Measure
between CN101-5 (+) and ground (
−
).
Make one print while monitoring the meter.
The meter swings from +24 VDC to 0 and
back to +24.
Y
N
Go to BSD 7.4 in Section 7 and trouble-
shoot the Feed Solenoid signal (CN101-5)
for a short to ground.
If no short exists, replace the PCU PWB.
If the problem still exists, replace the Feed
Solenoid.
Set up the meter to read +24 VDC. Measure
between CN101-4 (+) and ground (
−
).
Make one print while monitoring the meter.
The meter swings from +24 VDC to 0 and
back to +24.
Y
N
Go to BSD 8.2 in Section 7 and trouble-
shoot the Registration Clutch signal and
+24 VDC Interlocked (CN101-4, 1) for an
open.
If no open exists, replace the PCU PWB. If
the problem still exists, replace the
Registration Clutch.
Check the following:
•
Obstructions torn paper etc. in the paper
path.
•
Mechanical drive problem.
Содержание DocuPrint C55
Страница 14: ...SERVICE CALL PROCEDURES 2 99 NOTES 1 6 DocuPrint C55 C55mp NC60 Notes ...
Страница 56: ...OTHER FAULTS RAPs 2 99 NOTES 2 42 DocuPrint C55 C55mp NC60 NOTES ...
Страница 76: ...IMAGE QUALITY SPECIFICATIONS 2 99 NOTES 3 20 DocuPrint C55 C55mp NC60 NOTES ...
Страница 130: ...REPAIRS ADJUSTMENTS 2 99 NOTES 4 42 DocuPrint C55 C55mp NC60 NOTES ...
Страница 216: ...GENERAL PROCEDURES 2 99 NOTES 6 18 DocuPrint C55 C55mp NC60 Notes ...
Страница 252: ...GENERAL PROCEDURES 2 99 NOTES 6 54 DocuPrint C55 C55mp NC60 NOTES ...
Страница 272: ...GENERAL PROCEDURES 2 99 NOTES 6 74 DocuPrint C55 C55mp NOTES ...
Страница 274: ...GENERAL PROCEDURES 2 99 NOTES 6 76 DocuPrint NC60 NOTES ...