The Web Registration Module does not guide the paper. See the “motor overcurrent”
error icon on the display screen.
Material setup was not run after the web was changed.
Remedy:
1.
Activate material setup on Primary (Upstream) CiPress
.
2.
Perform Material Setup for Primary (Upstream) CiPress
3.
Activate material setup on Secondary (Downstream) CiPress.
4.
Perform Material Setup for Secondary (Downstream) CiPress
The Web Registration Module does not guide the paper. See the “timeout motor
activation” error icon on the screen.
• The web is not threaded in the CiPress
™
.
• There is no web tension.
Remedy:
• Thread the web. See the Web Threading Guide for more information.
• Ensure that there is tension on the web. See the Web Threading Guide for more
information.
All settings on the Web Registration Module are correct, but the Web Registration Module
does not guide the paper.
The gain of the Web Registration Module was inadvertantly reduced to the minimum
value.
Remedy:
1.
Optimize Gain for Primary (Upstream) CiPress
.
2.
Optimize Gain for Secondary (Downstream) CiPress
5-11
Xerox
®
CiPress™ 325 / 500 Production Inkjet System
Customer Help Information
Problem Solving
Содержание CiPress 325
Страница 1: ...Xerox CiPress 325 500 Production Inkjet System Customer Help Information 5 0 Software August 2012...
Страница 16: ...Xerox CiPress 325 500 Production Inkjet System 1 8 Customer Help Information CiPress System...
Страница 28: ...Xerox CiPress 325 500 Production Inkjet System 2 12 Customer Help Information Power Management...
Страница 30: ...Xerox CiPress 325 500 Production Inkjet System 3 2 Customer Help Information Web Setup...
Страница 102: ...Xerox CiPress 325 500 Production Inkjet System 4 72 Customer Help Information Operating the CiPress User Interface...
Страница 191: ......
Страница 192: ......