Installation
Load Connection
Release 2.2
33
Proper connection of distributed loads is an important aspect of power supply
application. A common mistake is to connect leads from the power supply to one
load, from that load to the next load, and so on for each load in the system. In this
parallel power distribution
method, the voltage at each load depends on the current
drawn by the other loads and DC ground loops are developed. Except for low current
applications, this method should not be used.
The preferred way to distribute power is by the
radial distribution
method in which
power is connected to each load individually from a single pair of terminals
designated as the positive and negative distribution terminals. The pair of terminals
may be the power supply output terminals, the terminals of one of the loads or a
distinct set of terminals especially established for distribution. Connecting the sense
leads to these terminals will compensate for losses and minimize the effect of one
load upon another.
Inductive Loads
To prevent damage to the power supply from inductive
kickback, connect a diode (rated at greater than the supply’s output voltage and with
a current surge rating greater than or equal to the supply’s output current rating)
across the output. Connect the cathode to the positive output and the anode to return.
Where positive load transients such as back EMF from a motor may occur, connect
a transorb or a varistor (with a breakdown voltage approximately 10% higher than
the rated supply output) across the output to protect the power supply.
Output Cord
Strain Relief
Assemble the strain relief from supplied pieces and attach it to the DC output
connector on 150V, 300V, and 600V models to provide support for the output cord.
Parts Supplied
•
•
Two (2) pieces of 6 position, cap housing strain relief.
•
Two (2) #6-32 x 5/8 in. screws.
Содержание XKW 150-7
Страница 2: ......
Страница 3: ...Operating Manual for XKW 1000 Watt Series Programmable DC Power Supply ...
Страница 15: ...Features and Specifications Front Panel Controls Release 2 2 13 Figure 1 1 Power Supply Front Panel ...
Страница 24: ...Features and Specifications Specifications 22 Operating Manual for XKW 1kW Series Power Supply ...
Страница 38: ...Installation Local and Remote Sensing 36 Operating Manual for XKW 1kW Series Power Supply ...
Страница 56: ...Operation Using Over Temperature Protection OTP 54 Operating Manual for XKW 1kW Series Power Supply ...
Страница 59: ......