Installation
Basic Checks or Self-Tests
Release 3.0
47
4. Slowly turn the Current knob clockwise 1 or 2 turns. Slowly turn the Voltage
knob clockwise and observe both the front panel voltmeter and the DVM. Do not
exceed 10V.
5. Compare the DVM reading with the front panel voltmeter reading to verify the
accuracy of the internal voltmeter. Both readings should be the same within the
accuracy of the meters. The minimum control range is from zero to the
maximum rated output for the power supply model. Check that the Constant
Voltage (CV) annunciator is illuminated.
6. Press
OUT ON/OFF
to turn the DC output OFF.
Current Mode
Operation
Check
To complete the current mode operation check:
1. Ensure that the OUT OFF annunciator is illuminated. If OUT ON is illuminated,
press
OUT ON/OFF
.
2. Connect the DC shunt across the output terminals on the rear panel.
3. Connect the DVM across the DC shunt.
4. Press
OUT ON/OFF
to turn the DC output ON.
5. Slowly turn the Voltage knob clockwise to a maximum reading of 10V.
6. Slowly turn the Current knob clockwise to a maximum reading of 10A.
7. Compare the DVM reading with the front panel ammeter reading using I=V/R
where I is the current, V is the DVM reading, and R is the DC shunt resistance.
The minimum control range is from zero to the maximum rated output for the
power supply model. Check that the Constant Current (CC) annunciator is
illuminated.
8. Press
OUT ON/OFF
to turn the DC output OFF.
9. Disconnect the DVM and the shunt.
WARNING- High Temperature Hazard
Ensure that the current output does not exceed the rating of the shunt or load wiring
during this test.
Содержание XDC
Страница 2: ......
Страница 3: ...Operating Manual for XDC 6000 Watt and 12000 Watt Series Digital Programmable DC Power Supply ...
Страница 22: ...List of Figures xx Operating Manual for XDC Series Power Supply ...
Страница 34: ...About The XDC Power Supply Overview of Operation 32 Operating Manual for XDC Series Power Supply ...
Страница 57: ...Installation Load Connections Release 3 0 55 Figure 2 11Output for 12000 Watt units High Voltage 300 600V ...
Страница 174: ...Remote Operation SCPI Commands for Digital Interfaces 172 Operating Manual for XDC Series Power Supply ...
Страница 180: ...Current Sharing 6000 Watt only Operation 178 Operating Manual for XDC Series Power Supply ...
Страница 216: ...SCPI Command Reference Expressions 214 Operating Manual for XDC Series Power Supply ...
Страница 228: ...GPIB Performance Specifications 226 Operating Manual for XDC Series Power Supply ...
Страница 253: ......