Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0
129
To check a triggered setpoint:
SOUR:VOLT:TRIG?
SOUR:CURR:TRIG?
SOUR:POW:TRIG?
To set limits:
SOUR:VOLT:LIM:HIGH <voltage>
SOUR:VOLT:LIM:LOW <voltage>
SOUR:CURR:LIM:HIGH <current>
SOUR:CURR:LIM:LOW <current>
SOUR:POW:LIM:HIGH <power>
SOUR:POW:LIM:LOW <power>
If the high end of the range was set to 5 volts, the command, SOUR:VOLT 10 would
return an error.
To check ranges:
SOUR:VOLT:LIM:HIGH?
SOUR:VOLT:LIM:LOW?
SOUR:CURR:LIM:HIGH?
SOUR:CURR:LIM:LOW?
SOUR:POW:LIM:HIGH?
SOUR:POW:LIM:LOW?
Example:
To set voltage to 5.5V and current limit to 100A, send the command:
:
VOLT 5.5; :CURR 100
Then check the output:
MEAS:VOLT?
5.500 (example readback, default unit V)
MEAS:CURR?
0.010 (example readback, default unit A)
MEAS:POW?
0.005 (example readback, default unit W)
Содержание XDC
Страница 2: ......
Страница 3: ...Operating Manual for XDC 6000 Watt and 12000 Watt Series Digital Programmable DC Power Supply ...
Страница 22: ...List of Figures xx Operating Manual for XDC Series Power Supply ...
Страница 34: ...About The XDC Power Supply Overview of Operation 32 Operating Manual for XDC Series Power Supply ...
Страница 57: ...Installation Load Connections Release 3 0 55 Figure 2 11Output for 12000 Watt units High Voltage 300 600V ...
Страница 174: ...Remote Operation SCPI Commands for Digital Interfaces 172 Operating Manual for XDC Series Power Supply ...
Страница 180: ...Current Sharing 6000 Watt only Operation 178 Operating Manual for XDC Series Power Supply ...
Страница 216: ...SCPI Command Reference Expressions 214 Operating Manual for XDC Series Power Supply ...
Страница 228: ...GPIB Performance Specifications 226 Operating Manual for XDC Series Power Supply ...
Страница 253: ......