Error Messages
Current Share Error Codes
222
Operating Manual for XDC Series Power Supply
Current Share Error Codes
Current share functionality is only available with the 6000 Watt power supply.
Table C.13
Current Share Error Codes
Error
code
Error Message Description
+1900 Current Share General Error
+1911
Current share master already online
A unit on the CANbus network has already been assigned the current share
master unit. Only one is allowed per network.
+1912 Current share slave lost
One of the connected current share slaves have not responded in time.
+1921 Current share master lost
The assigned master has not responded in time.
+1922 Current share slave connection refused
Connection as a slave on the current share network has been refused due to
one of the following reasons:
4 slaves are already online,
the voltage rating does not match those of the master’s,
the current rating does not match those of the master’s.
+1924 Current share data out of range
The voltage or current readback or setpoint values passed are out of range.
+1925 Current share slave output off by unknown
One of the slave’s output is off because of unknown reasons
+1926 Current share slave output off by command
One of the slave’s output is off because of a command from a remote source
or the front panel.
+1927 Current share slave output off by AC fail
One of the slave’s output is off because of an AC fail condition.
+1928 Current share slave output off by OTP (Over Temperature Protection)
One of the slave’s output is off because of an OTP condition.
Содержание XDC
Страница 2: ......
Страница 3: ...Operating Manual for XDC 6000 Watt and 12000 Watt Series Digital Programmable DC Power Supply ...
Страница 22: ...List of Figures xx Operating Manual for XDC Series Power Supply ...
Страница 34: ...About The XDC Power Supply Overview of Operation 32 Operating Manual for XDC Series Power Supply ...
Страница 57: ...Installation Load Connections Release 3 0 55 Figure 2 11Output for 12000 Watt units High Voltage 300 600V ...
Страница 174: ...Remote Operation SCPI Commands for Digital Interfaces 172 Operating Manual for XDC Series Power Supply ...
Страница 180: ...Current Sharing 6000 Watt only Operation 178 Operating Manual for XDC Series Power Supply ...
Страница 216: ...SCPI Command Reference Expressions 214 Operating Manual for XDC Series Power Supply ...
Страница 228: ...GPIB Performance Specifications 226 Operating Manual for XDC Series Power Supply ...
Страница 253: ......