Indicator LEDs on the Onboard Display Panel and Optional Remote Panel
975-0401-01-01
3–5
Table 3-1
Interpreting Fault and Warning Indicators
Fault or Warning
Condition
Temp
Fan
AC
Battery
Fuse
Charger
Remote
Fault
Solution
High Battery Temp
warning (>50°C)
•
Check the batteries. Do not charge a battery that is
rated other than 12 V nominal for all 12 V chargers or
24 V nominal for all 24 V chargers. Check that the
battery type and temperature settings match the actual
battery and its conditions.
•
Disconnect the battery (or batteries) to stop charging.
•
Allow the battery (or batteries) to cool to normal
operating temperature. If the temperature increases
further, the battery charger will display a fault, and
shut down. The battery (or batteries) may become
damaged if overheated. See Appendix A,
“Specifications”.
Flashing LED
Solid LED
F
u
s
e
C
h
g
r
R
e
m
TC2 Series BattChg Owners Guide.book Page 5 Tuesday, July 1, 2008 11:55 PM