Indicator LEDs on the Onboard Display Panel and Optional Remote Panel
975-0401-01-01
3–9
Locked Fan fault
•
Check for anything impeding the fan located between
the DC output terminals and AC wiring cavity. Safely
remove any obstructions when the charger is off.
•
No further action required. The fan will resume its
operation automatically and the charger will resume
charging after one minute. If the fault remains, call
Xantrex for support.
Loss of Remote
Connection warning
•
Reconnect the communication cable to the port. It
takes 15 minutes to re-establish communication.
Reverse Polarity Fuse
fault
•
Check for reverse battery polarity (negative
connected to negative, positive connected to positive
is correct) at battery and charger output terminals.
•
Disconnect AC and DC sources before replacing the
fuse on the charger. See “Replacing the DC Output
Fuse” on page 3–11.
Internal fault
•
Call Xantrex for support.
Flashing LED
Solid LED
Table 3-1
Interpreting Fault and Warning Indicators
Fault or Warning
Condition
Temp
Fan
AC
Battery
Fuse
Charger
Remote
Fault
Solution
F
u
s
e
C
h
g
r
R
e
m