Introduction
1–12
975-0401-01-01
Low Battery Temp
fault (< -25°C)
See Figure 1-6.
AC input out of range
Warning (<104V and
>90V) or
(<264V and >255V)
See Figure 1-5.
AC input out of range
fault
(<90V or >265V)
See Figure 1-5.
AC frequency out of
range fault
(<45 Hz or >65 Hz)
High Battery voltage
fault (>16.6V)
High Charger Temp
warning (>50°C)
High Charger Temp
fault (>70°C)
Locked Fan fault
Loss of Remote
Connection warning
Flashing LED
Solid LED
Table 1-1
Fault and Warning Indicators
Fault or Warning
Condition
Temp
Fan
AC
Battery
Fuse
Charger
Remote
Fault