Wiring the Inverter
3–8
975-0466-01-01
7. Connect the Active conductor to the terminal marked with 2.
Terminal 3 is not used.
8. After ensuring all the wires are tightened in their terminals, screw the shell
onto the female terminal.
9. Replace the remaining components of the female cable connector, ensuring a
tight seal.
10. Tighten the pressing screw.
To connect the AC connector to the GT Inverter:
1. Line up the notch on the female AC cable connector with the connector on the
GT Inverter.
2. Insert the AC cable connector into the connector on the GT Inverter.
3. Secure the connector by turning the outer ring.
Figure 3-5
AC Connector (Female)
Figure 3-6
AC Connector Terminals
Female terminal
Shell
Seal
Pinch ring
Pressing screw
Outer ring
Notch
AC connector terminals
(see Figure 3-6)
Protective Earth
wire
Not used
Neutral wire
Active Phase
L wire
CAUTION
For the inverter to meet regulatory requirements and for weather protection, the
communication ports cover must be installed. If no communications wiring is required,
install the communication ports cover when all DC and AC connections are complete (see
Figure 3-12). If communications wiring is required, install the cover after completing the
communcations wiring (see “Communications Wiring for Multiple Inverters” on
page 3–10 or “Communications Wiring for Monitoring a Single Inverter” on page 3–16).
Содержание GT2.8-AU-QC-230
Страница 1: ...Xantrex Grid Tie Solar Inverter Owner s Manual GT2 8 AU QC 230 GT5 0 AU QC 230 ...
Страница 2: ......
Страница 3: ...Xantrex Grid Tie Solar Inverter Owner s Manual ...
Страница 8: ...vi ...
Страница 14: ...Contents xii 975 0466 01 01 ...
Страница 16: ...xiv ...
Страница 18: ...xvi ...
Страница 58: ...4 4 ...
Страница 70: ...Monitoring the Inverter 5 12 975 0466 01 01 ...
Страница 76: ...Maintenance and Troubleshooting 6 6 975 0466 01 01 ...
Страница 82: ...A 6 ...
Страница 89: ......