975-0767-01-01
55
Warning Messages
For error code
:
after the LBCO shutdown delay, the unit
will immediately stop inverting
For error codes
to
:
the unit will stop inverting
Low battery voltage detected
depending on setting, see
“Operating Limits” on page 51.
Inverting
•
Check battery status and recharge if necessary.
•
Check for proper DC cable sizing.
•
Check for loose connections and tighten if necessary.
AC output overload warning
Inverting
•
Reduce the loads connected to the AC outlet of the unit.
Fan lock alarm
Inverting
•
Check the fan for any obstruction and remove it.
Large debris which may enter through the fan grille may impede the
fan blades from turning. When removing debris, do not insert your
fingers inside the grille. Remove power from the inverter first
before attempting to remove the debris.
to
General fault detected
Inverting and bypass
•
Check the fan for any obstruction and remove it.
•
If there is no issue with the fan, disconnect the unit from its DC and
AC power sources, then reconnect, and then restart the unit. Perform
“Step 7: Testing Your Installation” on page 32.
•
If fault detection persists, contact customer service.
Table 6
Error Codes Displayed on the LCD Screen
Error Code
Condition
Mode
Action
Freedom X Owners Guide.book Page 55 Wednesday, May 11, 2016 10:32 AM
Содержание Freedom X 1200 120VAC
Страница 2: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM...
Страница 12: ...Freedom X Owners Guide book Page x Wednesday May 11 2016 10 32 AM...
Страница 14: ...Freedom X Owners Guide book Page ii Wednesday May 11 2016 10 32 AM...
Страница 77: ...Freedom X Owners Guide book Page i Wednesday May 11 2016 10 32 AM...