Freedom Inverter/Charger Operation
Faults and Warnings
A fault affects the operation of the unit. A
manual fault requires user intervention by clearing the condition and
then pressing the
CLEAR FAULT RESET
button on the inverter/
charger’s front panel. See the
Xanbus System Control Panel
Owner’s Guide
for information on clearing faults from the SCP.
A warning alerts you to a condition that could possibly affect
operation of the unit.
Operating Limits for Inverter Operation
Temperature
The Freedom SW 230V series of inverter/chargers
will operate at full rated power continuously at 25 °C. See
“Specifications” on page 85 for full details. In higher ambient
temperatures, if the loads draw full power for an extended period of
time, the unit may shut down to protect itself against overheating.
The Freedom SW 230V series of inverter chargers feature a surge
rating of 200% of rated power for five seconds at 25 °C. Operating
the inverter/charger in conditions outside of power and temperature
limits, however, will result in thermal shutdown and/or significantly
decreased performance. In addition, operation in this range is
outside the ratings covered by the regulatory approvals of the
product.
Pass-through AC
The Freedom SW 230V model
inverters provide 230 volts/50 Hz of AC power during invert mode
to operate AC loads of the same rating. When a 60 Hz AC source is
applied to the Freedom SW 230V inverter/charger, the AC that is
passed-through remains at a frequency of 60 Hz.
Difficulty on starting loads
The inverter/charger should be able
to operate all AC loads rated at or below its power rating. Some
high horsepower induction motors used in pumps and other motor-
operated equipment require very high surge currents to start, and the
inverter/charger may have difficulty starting these loads.
Table 1
Front Panel Lights
Light
Illuminated
Color
Status
Action (or Status Item)
INVERTER
ENABLED
Steady
Green
If utility and generator AC is
unavailable and operating
conditions are met, the
Freedom SW 230V will
produce AC voltage to power
loads.
You can run your appliances
from the inverter.
GEN
SUPPORT
Flashing
Green
The inverter is assisting a
generator in powering loads.
You can run your appliances
from the inverter.
AC IN
Steady
Green
When the Freedom SW
230V is connected to a
qualified AC source or a
generator, the External AC
light illuminates.
You can run your appliances
from an AC source like the
utility grid (shore power) or
a generator.
CHARGING
Flashing
Green
Freedom SW 230V is
connected to a qualified AC
source, is charging and
passing power to AC loads.
Your battery bank is being
replenished and AC loads are
receiving power.
FAULT
Steady
Red
A fault has occurred on the
network.
Investigate and clear the fault
condition.
WARNING
Flashing
Red
A warning is detected.
Investigate by examining
warning logs on SCP.
IMPORTANT:
If you are having problems with any of your loads, refer to
“Inverter Applications” on page 72.
FSW 230V Owners Guide.book Page 15 Tuesday, August 7, 2018 9:38 AM
Содержание Freedom SW 230V 815-3524-02
Страница 2: ...FSW 230V Owners Guide book Page ii Tuesday August 7 2018 9 38 AM...
Страница 10: ...FSW 230V Owners Guide book Page viii Tuesday August 7 2018 9 38 AM...
Страница 14: ...FSW 230V Owners Guide book Page iv Tuesday August 7 2018 9 38 AM...
Страница 98: ...FSW 230V Owners Guide book Page 84 Tuesday August 7 2018 9 38 AM...
Страница 103: ...FSW 230V Owners Guide book Page i Tuesday August 7 2018 9 38 AM...