975-0696-01-01
13
Freedom Inverter/Charger Operation
Start Up Behavior
When the Freedom SW 230V is powered up or has been reset, all of
the front panel lights illuminate and remain on for a minimum of
five seconds. During this interval, the fans are also turned on as the
unit executes internal diagnostics.
The Freedom SW 230V inverter is disabled every time the unit is
powered up. After power up, the
INVERTER ENABLE
button (or
the SCP) can be used to enable or disable the inverter.
When a function is enabled, it is allowed to occur but other
conditions may have to be met before the function is activated or
turned on. For example, the charger function on the Freedom SW
230V may be enabled, but it will not charge unless qualified AC
power is present.
IMPORTANT:
Review the “Important Safety Instructions” on page iii
before operating the inverter/charger.
FSW 230V Owners Guide.book Page 13 Tuesday, August 7, 2018 9:38 AM