LAN CONTROL AND TROUBLESHOOTING

UP denotes ON.

EDID Switches that are marked in grey indicate the 

switch can be in any position.

Before copying output port EDID, ensure the matrix 

port is connected to a display - EDID copy will fail 

without connection to output device.

Matrix must be restarted for changes to DIP switch 

to take effect.

ii) Copying Output Port EDID

Example:

 To copy EDID from an HDMI display connected 

to matrix output port 1 to input port 2:

       

Set the EDID DIP switch to 000X ("X" position is 

unimportant for the setting), as per setting below.

       Reboot the matrix.

       Press the selection buttons on the matrix front panel 

to select input port 2 on output port 1 > the number LED 

number indicator will blink to confirm action.

       Press and hold the Enter button for approximately 

five seconds until the message CPY OK is displayed to 

confirm EDID copy is successful.

NOTE

       To apply EDID of the other HDMI displays to all 

the input ports, set the EDID DIP switch to the required 

position and reboot the matrix for the setting to take 

effect.

       Output port EDID can also be copied to input ports 

using the COM Control software. 

See EDID Settings for details.

WyreStorm MX-0808-PP-POH-4K is fully compatible with 

all market leading control systems with full integration 

protocols available for Enado, AMX, Control 4, Crestron 

and RTI.

Generally, the majority of HD distribution installation 

issues are either caused by minor connection 

errors, communication problems between devices, 

or when the transmission of high signal bandwidth 

is attempted using insufficient cable. 

Should you encounter any technical difficulties 

when installing and configuring the matrix, we 

are confident solutions can be found by working 

through the following troubleshooting checklist 

before seeking alternative technical support.

 

No Picture or Poor Quality Picture

1) Power

 – are the HDBaseT receivers showing power? 

All units should be powered either by the matrix or an 
optional external power supply in cases where PoH does 
not function.
 

NOTE 

 Display receivers do not need to be 

independently powered if part of an HDBaseT PoH 

extender set or MX-PP-POH Matrix solution.

 

Are all sources definitely powered and firmly connected?

2)

 If possible, always use test equipment prior to 

installation and to troubleshoot any problems.
 

3) Distance

 – Is the cable too long for the signal to be 

transmitted effectively? The HDBaseT classification used 
within the transmitters and receivers allow transmission 
of 1080p up to 100m/328ft and 4K up to 70m/230ft 
so make sure the cable distance matches the project 
requirements and is well within the maximum transmission 
distance of the signal.
 

NOTE 

 If approaching the limits of the transmission 

capabilities, transmission should be extended by 

using another extender set to ensure the signal 

reaches its destination effectively.

4) Cable Joins

 – Joins in the cable run or RJ45 

connectors can impact on signal strength, resulting in 
reduced transmission that may manifest itself in incorrect 
picture quality, picture dropping out or a complete lack of 
picture

5) Cable Choice and Signal Reduction

 – Are stranded 

patch leads being used as interconnects between patch 

14.     Troubleshooting

Default EDID Setting

Copies HDMI display EDID to 
the selected input port 

1 2 3 4

ON DIP

1

2
3

4

5

6

13.     LAN Control

Содержание MX-0808-PP-pOH-4K

Страница 1: ...tion Manual WyreStorm 4K Matrix Solutions MX 0808 PP pOH 4K 4K HDBaseT 5 Play 8x8 Matrix including PoH Bidirectional IR and RS232 Serial Control Thank you for choosing this WyreStorm product Please re...

Страница 2: ...full compatibility with leading third party control systems including the WyreStorm Enado multi platform browser based control interface Seeking to avoid compatibility issues encountered by some manu...

Страница 3: ...single Cat5e 6 7 UTP cable to each display point for ease of installation Conforms to IEEE 568B standards Each HDMI port also supports DVI signals Each Output port can be fed to multiple displays cas...

Страница 4: ...Switch 1 x Ethernet 1 x LAN 1 x RS232 1 x RS485 Output Bandwidth Signaling Rate 6 75Gbps Input video Signal 0 5 1 0 volts p p Input DDC Signal 5 volts p p TTL Maximum Pixel Clock 297MHz Video Impeden...

Страница 5: ...will not be made unless Enter is pressed Cable Type Range Supported Video Cat5e 6 100m 328ft 1080p 60Hz 36bit Deep Colour 70m 230ft 1080p 60Hz 48bit Deep Colour 1080p 60Hz 3D 4Kx2K 30Hz 4 2 2 chroma s...

Страница 6: ...matrix via LAN Telnet Web GUI 8 RS232 port Connect to a RS232 device such as a PC or control system device with the supplied USB to UART cable or a direct serial cable for matrix control or firmware...

Страница 7: ...r IRRX Receiver HDMI UTP Cat5e 6 7 Control System Additional control via RS232 LAN RS485 08 IR RX receiver and IR TX emitter placed discretely on the display with a clear line of sight to the remote h...

Страница 8: ...tional and should be used only if there is insufficient power from the transmission device Power is passed along the Cat5e 6 7 cable so the quality of termination cable and condition are essential for...

Страница 9: ...caled down to compatible stereo PCM for those that cannot without sacrificing the integrity of the distribution Visit wyrestorm com for more information on 4K HD scaling and Dolby downmixing The matri...

Страница 10: ...ched to an alternative matrix control mode Remote Control at the Display End Remote IR When controlling the matrix remotely from the display side the matrix automatically detects which particular outp...

Страница 11: ...between the input sources connected to the matrix for each individual output display So for example using the previous next buttons for 1 allows you to select the source to be set to display 1 manu al...

Страница 12: ...ctions Options in the Message R eceive window include Press to view the current condition of all output ports Press to delete the previous received message iii Send Message Window In the Send Message...

Страница 13: ...n a COM Port is connected the only option will be to Disconnect and vice versa Note In Connect Status area Connected indicates that the matrix is connected to the COM port and communication is enabled...

Страница 14: ...t successfully by using Netfinder Logging in to matrix control screen or Telnet sections for further details EDID Settings The EDID SET window allows users to access and configure EDID settings that c...

Страница 15: ...The IR Matrix allows the creation of different IR paths to remotely control the IR devices such as source or display devices using each device remote control from the matrix location 1 2 3 4 1 UTP Lon...

Страница 16: ...le to distin guish wher e the remo te hand set is being used to chang e INPU TS and OUTP UTS and is able to switc h accor dingly depe nding on the user s locati on As such the funct ion of the hand se...

Страница 17: ...ransmit serial data to PC Baud rate 9600bps Data bits 8bits Parity None Stop bits 1 Flow control None Com Port Setting COM CTL After fully connecting all inputs and outputs to the matrix and installin...

Страница 18: ...t 1 Intput 2 Intput 3 Intput 4 Intput 5 Intput 6 Intput 7 Intput 8 03 EDID Set MX0808 PP 1 2 17 Technical Support support wyrestorm com US 866 677 0053 EU 44 0 1793 230 343 source for Output 4 MX0606...

Страница 19: ...ce remote handsets IR emitters must be firmly connected to correct ports of matrix and securely attached directly over device IR sensor windows All IR cables should be free of bends kinks tangles knot...

Страница 20: ...s likely that you will not need to change the setting HINT If your remote control is not working before changing the battery try changing the System Code on the handset in case it has accidentally bee...

Страница 21: ...both request and send the required information For example a display will communicate 1080p capability with 2ch audio which the source device will accept and output the correct format for the display...

Страница 22: ...ignal bandwidth is attempted using insufficient cable Should you encounter any technical difficulties when installing and configuring the matrix we are confident solutions can be found by working thro...

Страница 23: ...or swapping the outputs of the matrix switch used If the problem remains on the same screen this may be caused by a connection problem between matrix and display turn off all equipment and swap the si...

Страница 24: ...ents included with your purchase or check compatibility of third party control systems with your WyreStorm dealer 6 IR dropout issues these can be due to exterior influences emitting infrared radiatio...

Страница 25: ...SPEED or category 2 HDMI cables that have been tested to perform at speeds of 340Mhz or up to 10 2Gbps which is the highest bandwidth currently utilised over an HDMI cable and can successfully handle...

Страница 26: ...d unless such information is provided Should you feel your product does not function adequately due to defects in materials or workmanship we referred to as the warrantor will for the length of the pe...

Страница 27: ...over HDBT TMDS Transition Minimized Differential Signal TV Television UART Universal Asynchronous Receiver Transmitter GLOSSARY 2 There are no express warranties except as listed under limited warran...

Страница 28: ...Reference Log Input Reference Log 27 Technical Support support wyrestorm com US 866 677 0053 EU 44 0 1793 230 343 INPUT REFERENCE LOG INPUT Input number on Matrix Source Location Source Details Sourc...

Страница 29: ...Reference Log 28 Technical Support support wyrestorm com US 866 677 0053 EU 44 0 1793 230 343 OUTPUT REFERENCE LOG OUTPUT Output number on Matrix Output Location Display Details Display Resolution Aud...

Страница 30: ...30 Technical Support support wyrestorm com US 1 866 677 0053 EU 44 0 1793 230 343 INSTALLATION NOTES 22 Installation Notes...

Страница 31: ...31 Technical Support support wyrestorm com US 1 866 677 0053 EU 44 0 1793 230 343 INSTALLATION NOTES...

Страница 32: ...ms Parkway Suite 104 Memphis TN 38133 Tel 901 384 3575 Fax 901 384 3574 Unit 22 Ergo Business Park Swindon Wiltshire SN3 3JW UK Tel 44 0 1793 230 343 Fax 44 0 1793 230 583 WyreStorm Technical Support...

Отзывы: