PULSE measurement
▸
Set the selector switch
[9]
measuring range to
“
PULSE
“.
▸
Set positive or negative using the cylinder-selec-
tion (CYL) button
[4]
.
▸
Plug the black measuring lead into the COM jack
[5]
.
▸
Plug the red measuring lead into the V/Ω input
jack
[6]
.
▸
Connect the measuring leads to the circuit being
tested.
3
The measurement result is output at the display
[1]
.
PULSE measurement
Measuring
range
Resolution
Accuracy
0.1 ms – 40 ms 0.01 ms
± 2.0 % + 5 d
Max. input voltage: 120 V
RMS
HOLD function
Use the HOLD function of the device to "freeze" a
measurement.
▸
Press the HOLD button
[3]
to "freeze" the current
display.
3
You can disconnect the measuring leads from the
test object and then read the measurement result
from the display.
▸
Press the HOLD button
[3]
again to return to
normal operation.
Automatic and manual measurement
range selection
If the display indicates "
AUTO
“, measuring range
selection is automatic.
▸
To set the measuring range selection to manual,
press the RAN button
[11]
.
▸
To again set the measuring range selection to
automatic, press and hold the RAN button.
Maintenance / Care
WARNING !
Risk of injuries or property damage
due to improper actions.
¾
Do not open the device.
¾
Only open the device, to change
the battery or fuse.
¾
Observe the relevant safety and
accident prevention regulations
during all maintenance and
servicing work.
Cleaning
Attention !
Never use aggressive cleaning agents or solvents
for cleaning!
▸
Clean the device using a damp cloth and a mild
domestic cleaning agent.
Battery changing
Attention !
Only use the batteries and fuses specified in the
“Technical data” chapter!
▸
Disconnect the measuring leads!
▸
Undo the three screws on the rear side of the
device and open the housing.
▸
Remove the discharged battery and insert a new
battery (1 × 9 V battery 6F22).
▸
Close the housing and screw the screws back in.
Fuse replacement
▸
Disconnect the measuring leads!
▸
Undo the three screws on the rear side of the
device and open the housing.
▸
Remove the defective fuse and insert a new fuse.
▸
Close the housing and screw the screws back in.
Содержание 0715 53 440
Страница 3: ...1 2 3 4 5 6 7 9 8 12 11 10 I 3...
Страница 4: ...4...
Страница 104: ...104 GR W rth 3 1...
Страница 105: ...105 50 V AC 120 V DC 30 IR 50 V AC 120 V DC W rth...
Страница 176: ...176 BG W rth 3 1...
Страница 177: ...177 50 V AC 120 V DC 30 IR 50 V AC 120 V DC W rth...
Страница 212: ...212 RU W rth 3 1...
Страница 213: ...213 50 120 30 50 120 W rth...
Страница 219: ...219 3 1 36 PULSE 9 PULSE CYL 4 COM 5 6 3 1 PULSE 0 1 40 0 01 2 0 5 120 HOLD HOLD HOLD 3 3 3 AUTO RAN 11 RAN 1 9 6F22...
Страница 239: ......