Intended use
The device is intended solely for measurements on
vehicles with 6 V, 12 V or 24 V on board voltage.
The user alone is responsible for damage
resulting from improper use.
Measurement categories
The following measurement categories are defined
according to standard EN 61010-1:
Measurement category CAT II
Measurements on circuits that have a direct connec-
tion via a plug with a low voltage network. Typical
short-circuit current < 10 kA.
Measurements on circuits directly electrically con-
nected to the mains via plugs in domestic, office and
laboratory applications.
Measurement category CAT III:
Measurements performed on the mains installation
of a building (stationary consumers with non-plugga-
ble connection, connection to the distribution board,
built-in devices in the distribution board). Typical
short-circuit current < 50 kA.
Measurements on building wiring installations:
Fixed installations, distribution boards, devices per-
manently connected to the distribution board.
Measurement category CAT IV:
Measurements on the source of the low voltage
installation (meter, main connection, primary over-
current protection). Typical short-circuit current >>
50 kA
Measurements on the source of the low voltage
installation:
meter, primary overcurrent protection, main
connection.
Device elements
Overview [Fig. I]
1
LCD
2
Zero point comparison (REL)
3
HOLD-key / backlight
4
Cylinder selection (CYL)
5
COM jack (ground)
6
V/Ω input jack
7
20 A measuring jack
8
mA measuring jack
9
Selection switch
10
Selection button (Select)
11
RAN button
12
HZ/% button
Operation
Direct current measurement
▸
Set the selector switch
[9]
measuring range to
V
.
▸
Plug the black measuring lead into the COM jack
[5]
.
▸
Plug the red measuring lead into the V/Ω input
jack
[6]
.
▸
Connect the measuring leads to the test object.
3
The multimeter automatically searches for the most
favourable measurement range.
3
The instantaneous measured value and its polarity
are output to the display
[1]
.
Measuring tolerances
Accuracy specification in ± (% of the
reading (= rdg) + indication error in dig-
its (=d = number of the smallest digits)).
DC voltage
Measuring
range
Resolution
Accuracy
400 mV
0.1 mV
± 0.5 % rdg + 4 d
4 V
0.001 V
40 V
0.01 V
120 V
0.1 V
Input resistance: 10 MΩ.
Overvoltage protection: 120 V
RMS
Содержание 0715 53 440
Страница 3: ...1 2 3 4 5 6 7 9 8 12 11 10 I 3...
Страница 4: ...4...
Страница 104: ...104 GR W rth 3 1...
Страница 105: ...105 50 V AC 120 V DC 30 IR 50 V AC 120 V DC W rth...
Страница 176: ...176 BG W rth 3 1...
Страница 177: ...177 50 V AC 120 V DC 30 IR 50 V AC 120 V DC W rth...
Страница 212: ...212 RU W rth 3 1...
Страница 213: ...213 50 120 30 50 120 W rth...
Страница 219: ...219 3 1 36 PULSE 9 PULSE CYL 4 COM 5 6 3 1 PULSE 0 1 40 0 01 2 0 5 120 HOLD HOLD HOLD 3 3 3 AUTO RAN 11 RAN 1 9 6F22...
Страница 239: ......