Overview of the DEP-100S
1 - 10
DEP-100S Data Entry Panel
Note:
In some weld devices, the MedLAN address is determined
by the weld control hardware. Refer to the Operator’s
Manual provided with your weld device.
P
OWER
-
UP
Applying power to the DEP-100S shows a display similar to this
example (for HHT program D07005 or greater):
One or more HHTs can operate on the MedLAN network.
HHT#nnn
identifies the network address of this particular HHT.
Any number of HHTs can operate on a network. However,
adding devices causes the polling time to increase. Generally,
you will use one HHT for all monitoring and programming, with
a practical limit of four HHTs.
The last two digits of the program number
(
pgm #
)
indicate the
revision level of the DEP-100S software. The number preceded by
L
is the Loader program number (which enables a WTC
technician to reload the software in the DEP-100S via your
communication network). The date
(
mm/dd/yy
)
shows when
the revision was released.
N
ETWORK
P
OLLING
After a few seconds, the DEP-100S polls each device to determine
which ones are active. It also checks the software program for the
weld control, to verify that it is compatible with the program in
the DEP.
The DEP-100S polls the WCU to determine the WCU ID
(program number, device type, revision number and hardware
compatibility) and the fault information stored in each weld
control’s battery-backed RAM memory.
HHT #200
........................................
Programming Interface
D07005 0001
wcu #00
T96312-00-01 66636M1
........................................
F1 F2
F3 F4