3.5.1.5 Data Communication
NOTICE
Damage to the product due to overvoltage!
Overvoltage can be generated by lightning, by capacitive or inductive
interferences of another electric systems.
•
Ensure that a surge arrester is available, if an Ethernet cable
is routed to the control card.
The data communication with the product is provided via the network connection of the
control card.
Required material (not included in scope of delivery):
•
Network cable with RJ45 plug
Figure 15: Connection data communication
Pos.
Description
1
Control card
2
Ethernet connection
3
Option EtherCAT interface
4
Input Option EtherCAT interface
5
Output Option EtherCAT interface
Procedure:
1.
Route
the cable through the cable entry grommet.
2.
Connect
the cables according to Figure 15.
3.
Lead
the cables downwards at the inner side of the cabinet.
4. If necessary,
fix
the cables with cable straps.