1A
2A
3A
4A
5A
6A
MRTALP4-DC3: #35058AUS
Rev 1.0/2-21
36
T
O
R
EPLACE
P
AD
I
NSERTS
IN
VPFS625 P
ADS
If the lifter has VPFS625 vacuum pads, replace pad inserts as follows:
1) Remove the lock nuts and washers that secure the top plate to the face plate of the pad
assembly (fig. 1A).
2) Remove the top plate (fig. 2A).
3) Remove the old pad insert (fig. 3A).
Note: Save the filter screen (circled in fig. 3A).
4) Install the new pad insert, making sure the smooth side of the insert is facing down
(fig. 4A).
Note: The new insert will compress to take on the form of the old one.
5) Make sure to place the air-line connector (circled top in fig. 5A) over the filter screen hole
(circled bottom in fig. 5A).
6) Reinstall the top plate, washers and lock nuts (fig. 6A).
7) Tighten all lock nuts securely.
Note: Replace worn nuts as needed.