Product
Description
Designed for use with hoisting equipment, MRTALP4-DC3 lifters support loads using vacuum and
manipulate loads using manual 180° rotation and mechanically assisted, manual 90° tilt motions.
Model Number
MRTALP4625DC3
MRTALP410TDC3
Vacuum Pads
(4 each, standard rubber)
6" x 25" [15 cm x 64 cm] nominal diiameter
(Model VPFS625)
1
1...... Standard with replaceable pad inserts for rough or textured surfaces (see
).
10" [25 cm] nominal diameter
(Model VPFS10T)
2
2...... Standard with replaceable sealing rings for rough or textured surfaces (see
Pad Spread
---------------------------- (to outer edges) ----------------------------
Maximum
36" x 92¾" [92 cm x 235 cm]
45¾" x 78¾" [116 cm x 200 cm]
Minimum
20" x 92½" [51 cm x 235 cm]
25¾" x 78¾" [65 cm x 200 cm]
Lifter
Weight
114 kg
92 kg
Maximum
Load Capacity
3
3...... The Maximum Load Capacity is rated at a vacuum of 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces with a friction coefficient of 1. Pad
compound, load rigidity, strength, surface conditions, overhang, angle, center of gravity and temperature can also affect the lifting capacity. A “qualified
person” should evaluate the effective lifting capacity for each use (see definition under
270 kg
Power System
12 volts DC, 5.5 amps
Battery Capacity
18 amp-hours
Rotation
Capability
Manual, 180°, with latching at every 30° of revolution (when required)
Tilt
Capability
Manual, 90°, with four-bar tilt linkage that provides mechanical advantage and automatic latching in
upright position
Product
Options
Available
with Pad Frame Extension Arms and Pad Frame Rocker Arms for installing roof panels.
See separate instructions about these and other options.
Operating
Elevation
Up to 6,000' [1,828 m]
Operating
Temperatures
32° – 104° F [0° – 40° C]
Service Life
20,000 lifting cycles, when used and maintained as intended
4
4...... Vacuum pads, filter elements and other wear-out items are excluded.
Software Version
Intelli-Grip
®
7.6
Design Standard
Compliant with AS 4991. Note: Each circuit of the Dual Vacuum System complies with the capacity
requirements of this Standard.