2.   installation

2.1  tools, resourCes and materials

• 

(Percussion) drilling machine

• 

Drill bits, suitable for the drilling substrate and the mounting pieces

• 

Ratchet (catrake) with extension, SW 13 and SW 17 sockets (if M12: SW 19)

• 

SW 4, SW 5 and SW 10 Allen keys

• 

SW 13 fork spanner

• 

Flat SW 17 ring spanner (if with tilting device) 

• 

Slotted screwdriver 

• 

Crosshead screwdriver No. 2

• 

Spirit level and string for alignment

• 

String for aligning the feet and posts

• 

Test cable, resp. adjustment set (for initial operation)

2.2. preparing the installation

Secure the installation zone (the secured zone must be at least equivalent to the size of the fully deployed awning).

Before beginning installation, a check must be made to ensure that the installation subsurface is capable of taking 

this load. If significant differences make the safe installation of the awning seem doubtful, please consult the ma-

nufacturer of the system and a mounting/installation specialist.

If the information above is not observed, the awning system may fall down and put the health of persons at risk!

2.3.  Wind resistanCe Classes

Definition: 

DIN EN 13561 Item 4.3. defines different wind resistance classes for awnings. The classification 

depends on the quality of the product. The higher the class, the better the quality of the product.

Wind resistance class

Description 

Wind force 

Wind speed

Class 0

undefined, product not tested or unsuitable

Class 1

Moderate wind

4 (according to Beaufort wind scale)

20 - 27 km/h

Class 2

Fresh wind

5 (according to Beaufort wind scale)

29 - 38 km/h

Class 3

Strong wind

6 (according to Beaufort wind scale)

39 - 49 km/h

Classification of the WINGlINE awning:

 

Version /

extended length

1500 mm 2000 mm 2500 mm 3000 mm 3500 mm 4000 mm 4500 mm

Wind class without 

VarioVolant

3

3

3

3

3

3

2

Wind class with 

VarioVolant

3

3

3

3

3

2

Downgrading the wind class of the awning due to poor installation conditions is only permitted in extreme cases, and then 

only with the agreement of the end user.

Содержание WINGLINE

Страница 1: ...MOUNTING INSTRUCTIONS Wingline MOUNTING INSTRUCTIONS Wingline 930113 _FR...

Страница 2: ...persons or for the function of the awning This symbol highlights important product information for the installation engineer Safety notes and important information are integrated in the text as approp...

Страница 3: ...f the awning seem doubtful please consult the ma nufacturer of the system and a mounting installation specialist If the information above is not observed the awning system may fall down and put the he...

Страница 4: ...in such a way that its axis lies at the system joint as shown on the above diagram Determine the position for the posts using the table Mounting with 2 posts System width System width System width A...

Страница 5: ...0 750mm 4800 150 650mm 150 200mm 150mm 4950 150 450mm 300 750mm 5000 150 450mm 150 200mm 5200 350 750mm 5300 150mm 5000 150 650mm 5400 150 200mm 5600 150 650mm 450 450mm 6000 150 650mm 150 650mm 150 4...

Страница 6: ...outsides Connect posts and foot with hex head screws washers and nuts through the predrilled holes If applicable pull the power supply cable for the driving gear through the tube of the post before in...

Страница 7: ...premounted arms and side parts into the posts and align laterally Fix cross tube with clamping screws 3 off per post in the posts Push the black counter bearing onto the end cap of the cloth roller Pu...

Страница 8: ...flange or with the cloth roller end cap into the counter bearing On the opposite side push the side part onto the cross tube Push the motor into the motor flange respectively the cloth roller end cap...

Страница 9: ...d out exclusively by a licensed electrical company 3 1 Adjusting the inclination headroom The awning is prebuilt in the factory with approximately 0 inclination If a steeper adjustment of the awning i...

Страница 10: ...the inner side mount the drop bar holder washers and nuts Tighten firmly for definite fixing of the drop bar holder in the drop profile Wind in awning to the back end position Also check that arms fol...

Страница 11: ...rrectly connected Check connection specialised company Thermal protection of the driving gear activated Wait for 15 20 mins then operate again Remote control batteries empty Check light signal on send...

Страница 12: ...ace of publication 8054 Graz Austria www woundwo com Austria Tel 43 0 316 2807 0 Fax 43 0 316 2807 8100 Germany Tel 49 0 5684 9232 0 WO WO Sonnenlichtdesign GmbH Co KG Hafnerstra e 193 8054 Graz AUSTR...

Отзывы: