ECRESO FM 5kW / 10kW, user manual
–
11/2021
Page 79
WorldCast Systems SAS - 20 avenue Neil Armstrong - 33700 Mérignac (Bordeaux Métropole) FRANCE
+33 (0)5 57 928 928
–
www.worldcastsystems.com
–
5.21.
Alarms
Current alarms are visible:
Front panel
Alarm menu
Only available when at least one alarm is active
Serial commands
Alarms
see section 7.2.5
Embedded web site
On applicable pages
All alarms can either be ON or OFF.
10 MHz SWITCH ALARM
(ALARM.10MSWITCH)
This alarm is on when there was a 10 MHz switch between the external source and the internal source.
1 dB ALARM
(ALARM.1DB)
This alarm is on when the RF is ON and the current forward power is below the set 1 dB power threshold. The 1 dB can
be user-set.
3 dB ALARM
(ALARM.1DB)
This alarm is on when the RF is ON and the current forward power is below the set 3 dB power threshold. The 1 dB can
be user-set.
AMBIENT TEMPERATURE ALARM
(ALARM.AMB)
This alarm is on when the current ambient temperature is above the set maximum ambient temperature. The max
ambient temperature can be user-set
LOW BATTERY ALARM
(ALARM.BATLOW)
This alarm is on when
the NVRAM battery’s level is low. It means the NVRAM battery needs to be changed.
COMMUNICATION ALARM
(ALARM.COMM)
This alarm is on when there is a communication fault with one of the units of the system. It only applies to Master unit
of modular transmitters and 1+1 systems.
CURRENT 1 or 2 ALARM
(ALARM.CUR1 / ALARM.CUR2)
This alarm is on when the MOSFET 1 or 2 current supplied by the PSU is over the max threshold.
EXCITER TEMPERATURE ALARM
(ALARM.EXC_TEMP)
This alarm is on when the temperature of the exciter is higher than the max threshold.
FAN 1 or 2 ALARM
(ALARM.FAN1 / ALARM.FAN2)
This alarm is on when the speed fan 1 or 2 is too slow.